09450-03100 PUMP ASSY, INJECTI Calibration Data


Rating:
20
Buy PUMP ASSY, INJECTI 09450-03100 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
TRACTOR V1512
Engine
V1512
Serial start-end
8406--8407
Info
Injector Nozzle

Components :

00.001
PUMP ASSY, INJECTI
PFR4M

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09450-03100
PUMP ASSY, INJECTI
PFR4M
17371-51011 KUBOTA
001
[01]
HOUSING SUB-ASSY,
005
[04]
HOLDER, DELIVERY V
006
[04]
SPRING, DELIVERY V
15221-51231 KUBOTA
007
[04]
O-RING
ID14.8
14611-51201 KUBOTA
008
[04]
GASKET, DELIVERY V
-9004
15221-51241 KUBOTA
008
[04]
GASKET, DELIVERY V
D11.8 9005-
15221-51241 KUBOTA
009
[04]
VALVE SUB-ASSY, IN
010
[04]
ELEMENT SUB-ASSY,
MK:5-595
011
[04]
SLEEVE, PLUNGER CO
15221-51382 KUBOTA
012
[04]
SEAT, SPRING, UPR
15221-51271 KUBOTA
013
[04]
SPRING, PUMP PLUNG
15221-51281 KUBOTA
014
[04]
SEAT, SPRING, LWR
015
[C]
PLATE, TAPPET ADJU
T0.6
14109-51301 KUBOTA
015
[C]
PLATE, TAPPET ADJU
T0.2
015
[C]
PLATE, TAPPET ADJU
T0.3
015
[C]
PLATE, TAPPET ADJU
T0.4
15221-51491 KUBOTA
015
[C]
PLATE, TAPPET ADJU
T0.5
015
[C]
PLATE, TAPPET ADJU
T0.25
015
[C]
PLATE, TAPPET ADJU
T0.35
016
[04]
TAPPET SUB-ASSY,IN
15221-51071 KUBOTA
016-001
[04]
TAPPET, INJECTION
15021-51990 KUBOTA
016-002
[04]
ROLLER, FEED PUMP
15109-52931 KUBOTA
016-003
[04]
PIN, INJECTION PUM
15021-51970 KUBOTA
017
[04]
PIN, INJECTION PUM
14611-51251 KUBOTA
018
[02]
PLATE
14611-51441 KUBOTA
019
[01]
RACK ASSY, CONTROL
15401-51061 KUBOTA
020
[03]
PLATE ASSY, ADJUST
-8807
14611-51391 KUBOTA
020
[03]
PLATE, ADJUSTING
8808-
14384-51391 KUBOTA
022
[03]
BOLT, W/WASHER
M6,L9.5 -9004
15221-91031 KUBOTA
022
[03]
BOLT, WASHER HEAD
M6,L8 9005-
023
[01]
SCREW, HOLLOW
15471-51321 KUBOTA
026
[02]
WASHER, FUEL PIPE
T1.5
15401-96652 KUBOTA
029
[04]
STOPPER, DELIVERY

Include in ##:

09450-03100 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
09450-03100 
17371-5101 
PUMP ASSY, INJECTI
0945003100 
17371-51011 
KUBOTA
PUMP ASSY, INJECTI

Test Calibration Data:

0945003100 17371-51011




Information:


Illustration 1 g00565418
4W-8471 Time Delay Relay
Use a 6V-7070 Digital Multimeter, a stopwatch, and a battery (8 volts to 40 volts) for this test.
Connect the positive lead of the voltage source to terminal (TD-4) of the time delay relay. Connect the negative lead to terminal (TD-3). If the test is done on an engine, the start/stop switch must be in the STOP position in order to power terminal (TD-6). All connections must be maintained until the tests are completed.
Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 1
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Connect the positive lead of the voltage source to terminal (TD-1). If the time delay relay is tested on the engine do not leave the voltage source hooked to terminal (TD-1) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 2
Terminals     Relay Position    
5-6     Open    
6-7     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 3
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    Note: If a jumper is normally installed across terminals (TD-2) and (TD-3), the jumper must be removed before performing Step 5.
Connect the positive lead of the voltage source to terminal (TD-2). If the time delay relay is tested on the engine, do not leave the voltage source on terminal (TD-2) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 4
Terminals     Delay Time of Relay Position    
0 to 8 seconds 10 seconds or more    
5-6     Closed     Open    
6-7     Open     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 5
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    
Remove the voltage source from terminal (TD-4). Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 6
Terminals     Relay Position    
5-6     Closed    
6-7     Open    

Have questions with 09450-03100?





Group cross 09450-03100