Provide table 3, table 4, table 7, table 8, and table 9.Provide the following list of information about the MMS configuration:
The MMS protocol for output is Modbus.
Ports for hardware are available. The ports have 9 pins. The RS-485 has one connection with 2 wires and two connections with 4 wires. The RS-232C has one handshaking connection and two connections without handshaking.
Provide the list of baud rates.
The network addresses can be a number between 1 and 247.
The system uses a serial cable that has 9 pins. The cable has shielding.Control System Inputs to PLC Redundant Relay Logic
Table 1
ISA TAG #    PLC CARD #    SENSOR DESCRIPTION    PLC REG ASSIGN    SIGNAL TYPE    ALARM    SHUT DOWN    SETPOINT TRIP    COMMENTS    
PRESSURE CONTACTORS    
PSLL-001     PLC01     Engine Low Oil Pressure: 144-0102     N7:01/07     DIGITAL         X     <
105 kPa (15.2 psi)     Low Speed    
PSLL-002     PLC01     Engine Low Oil Pressure: 144-0102     N7:01/07     DIGITAL         X     <
260 kPa (37.7 psi)     High Speed    
PSHH-003     PLC01     Engine High Crankcase Pressure: 117-1864     N7:07/11     DIGITAL         X     >
1 kPa (4.0 inch of H2O)     Enable When Fuel is On    
PSL-004     PLC02     Low Air Starting Pressure: 117-1864     N7:07/12     DIGITAL     X         <
750 kPa (108.8 psi)     Removed if Transducer is Ordered    
PSL-005     PLC02     Sea Water Low Pressure:     N7:01/08     DIGITAL     X         <
35 kPa (5.1 psi)     Removed if Transducer is Ordered    
PSL-006     PLC02     Low Jacket Water Pressure: 144-0102     N7:01/10     DIGITAL     X         <
20 kPa (2.9 psi) (Low RPM)
<
35 kPa (5.1 psi) (High RPM)     Removed if Transducer is Ordered    
PSL-007     PLC02     Low AC/OC Circuit Water Pressure: 144-0102     N7:01/12     DIGITAL     X         <
35 kPa (5.1 psi)     Removed if Transducer is Ordered    
SWITCHES/MISC CONTACTS    
YSL-001     PLC01     Low Battery Voltage: 7C-3508     N7:07/09     DIGITAL     X         < 22 VDC     Monitors Dc to MMS    
LSL-001     PLC02     Jacket Water Detection: 125-4340     N7:01/15     DIGITAL     X         Contact Close     Energizes RJWDA Relay    
HS-001     PLC01     Emergency Stop (Local)     N7:07/06     DIGITAL         X     Contact Close     Shuts Off Fuel And Air to Engine    
SS-001     PLC01     Engine Speed Switch Crank Terminate: 100-5675     I:1.0/9     DIGITAL             > 170 RPM & < 0 + 2 Sec        
SS-006         Engine Speed Switch Alarm Time Delay: 100-5675         DIGITAL             9 Sec After SS-001     Enables Alarms and Shutdowns    
SS-007         Engine Speed Switch Oil Pressure Step: 100-5675         DIGITAL             75%