Rating:
Information valve sub-assy, in Denso
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$23.00
17 Aug 2023
CN: lutong part plant
4Pcs Delivery Valves 0901401200 Injection Pump Pressure Valve 090140-1200 Compatible with HINO W04D HINO H06C-T
DICSCL PARCS Delivery Valve Part Number: 090140-1200, 0901401200 || Packing: 4pcs Delivery Valve. || 100% brand new and high quality Made High-quality steel materia. || Longer Service Life: High quality durability material and excellent crafts, as well as the applied series of tests in RD center before they were listed, provide a reliable operation and longer service life of this item. || Easy Replacement: Easy to install, you could use it directly.
DICSCL PARCS Delivery Valve Part Number: 090140-1200, 0901401200 || Packing: 4pcs Delivery Valve. || 100% brand new and high quality Made High-quality steel materia. || Longer Service Life: High quality durability material and excellent crafts, as well as the applied series of tests in RD center before they were listed, provide a reliable operation and longer service life of this item. || Easy Replacement: Easy to install, you could use it directly.
$32.00
17 Aug 2023
CN: lutong part plant
6Pcs Delivery Valves 0901401200 Injection Pump Pressure Valve 090140-1200 Compatible with HINO W04D HINO H06C-T
DICSCL PARCS Delivery Valve Part Number: 090140-1200, 0901401200 || Packing: 6pcs Delivery Valve. || 100% brand new and high quality Made High-quality steel materia. || Longer Service Life: High quality durability material and excellent crafts, as well as the applied series of tests in RD center before they were listed, provide a reliable operation and longer service life of this item. || Easy Replacement: Easy to install, you could use it directly.
DICSCL PARCS Delivery Valve Part Number: 090140-1200, 0901401200 || Packing: 6pcs Delivery Valve. || 100% brand new and high quality Made High-quality steel materia. || Longer Service Life: High quality durability material and excellent crafts, as well as the applied series of tests in RD center before they were listed, provide a reliable operation and longer service life of this item. || Easy Replacement: Easy to install, you could use it directly.
$413.70
04 Oct 2021
0.0022[0.00] Pounds
CN: New WFAANW
WFAANW Common Rail Outlet Valve 090140-1200 090140-1350 090140-1990 090140-090140-2220 090140-1470 096420-0550 (Color : 090140 1990)
WFAANW HOW TO BUY || Our Company || Our products are multi-certified and quality guaranteed. If you have any questions, please contact us by email.
WFAANW HOW TO BUY || Our Company || Our products are multi-certified and quality guaranteed. If you have any questions, please contact us by email.
Include in ##:
09010-04034
as VALVE SUB-ASSY, IN
Cross reference number
Part num
Firm num
Firm
Name
09014-01200
22103-1360
VALVE SUB-ASSY, IN
0901401200
22103-1360A
HINO
VALVE SUB-ASSY, IN
Information:
Diesel Engine Crankcase
Check oil level daily before starting engine and when refueling. Check with the engine either running or stopped as indicated on the oil level gauge. Add oil when the level drops to the add oil mark. Drain the crankcase every 10,000 miles while engine is warm and stopped. If equipped with a 13 qt. supplemental filter system the normal interval can be extended to 15,000 miles. Install drain plug. Diesel Engine Crankcase Lubricating Oil Filter
Change filter element every 10,000 miles. Drain the filter housing by removing drain plug. Loosen bolt on the cover and remove the housing and filter element. Inspect seal and install a new one if necessary. Wash the inside of the filter housing and install a new Caterpillar filter element. After draining crankcase remove filter cap and refill. See page 15 for quantity. Start engine and check for oil leaks at drain plug and filter housing. Diesel Engine Crankcase Breather
Remove breather tube cover and element. Wash with clean solvent or diesel fuel at each oil change period. Inspect seal and replace if necessary. Lubricating Grease
Use Multipurpose-type Grease which contains both 3 to 5% molybdenum disulfide conforming to MIL-M-7866, and a suitable corrosion inhibitor. NLGI No. 2 Grade is suitable for most temperatures. NLGI No. 1 or No. 0 are suitable for extremely low temperatures.Always clean fittings before lubricating.Fan Pulley Bearing
Lubricate every 10,000 miles. Lubricate through fitting until grease appears at relief fitting on front of fan hub. Wipe off excess grease. Water Pump Bearing
Lubricate every 10,000 miles. Lubricate through fitting until lubricant appears at relief fitting. Earlier engines have no relief fitting. Excess lubricant will appear at end of water pump shaft. Tachometer Drive
Lubricate every 10,000 miles. Remove plug. Install grease fitting and apply one stroke of lubricant through fitting.
Check oil level daily before starting engine and when refueling. Check with the engine either running or stopped as indicated on the oil level gauge. Add oil when the level drops to the add oil mark. Drain the crankcase every 10,000 miles while engine is warm and stopped. If equipped with a 13 qt. supplemental filter system the normal interval can be extended to 15,000 miles. Install drain plug. Diesel Engine Crankcase Lubricating Oil Filter
Change filter element every 10,000 miles. Drain the filter housing by removing drain plug. Loosen bolt on the cover and remove the housing and filter element. Inspect seal and install a new one if necessary. Wash the inside of the filter housing and install a new Caterpillar filter element. After draining crankcase remove filter cap and refill. See page 15 for quantity. Start engine and check for oil leaks at drain plug and filter housing. Diesel Engine Crankcase Breather
Remove breather tube cover and element. Wash with clean solvent or diesel fuel at each oil change period. Inspect seal and replace if necessary. Lubricating Grease
Use Multipurpose-type Grease which contains both 3 to 5% molybdenum disulfide conforming to MIL-M-7866, and a suitable corrosion inhibitor. NLGI No. 2 Grade is suitable for most temperatures. NLGI No. 1 or No. 0 are suitable for extremely low temperatures.Always clean fittings before lubricating.Fan Pulley Bearing
Lubricate every 10,000 miles. Lubricate through fitting until grease appears at relief fitting on front of fan hub. Wipe off excess grease. Water Pump Bearing
Lubricate every 10,000 miles. Lubricate through fitting until lubricant appears at relief fitting. Earlier engines have no relief fitting. Excess lubricant will appear at end of water pump shaft. Tachometer Drive
Lubricate every 10,000 miles. Remove plug. Install grease fitting and apply one stroke of lubricant through fitting.