09009-90440 SWITCH KIT, CONTRO Denso Cross


Rating:
76
Buy SWITCH KIT, CONTRO 09009-90440 genuine, new aftermarket engine parts with delivery

Information switch kit, contro Denso

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09009-90440
SWITCH KIT, CONTRO
001
[01]
SWITCH ASSY, CONTR
002
[01]
CLIP, CORD
003
[01]
CLIP, CORD
004
[02]
SCREW, W/WASHER
M4,L25
005
[01]
BOLT, W/WASHER
M5,L8
006
[01]
BOLT, HEXAGON
M6,L25
007
[01]
NUT, HEXAGON
M6,L5
008
[01]
PLATE, COVER

Cross reference number



Part num
Firm num
Firm
Name
09009-90440 
 
SWITCH KIT, CONTRO
0900990440 
ME016027 
MITSUBISHI
SWITCH KIT, CONTRO




Information:

FACE="Courier New">CONFIDENTIAL
TECHNICAL INFORMATION BULLETIN March 27, 2002
Engines 3516 (25Z, 5SJ, 7KM, CMD, 4XF)
3516B (1HZ, 7RN, 5AN, FDN, BDP,
6HN)
Component Code: 1404SUBJECT: Generator Stator Adapter Cracking on 3516 Diesel Generator Set
PROBLEM:
Certain SR4B single bearing generators may develop cracks in the adapter assembly. The generator adapter is the welded assembly, part of the generator stator, consisting of the front adapter ring that bolts to the flywheel housing and the individual support bars welded to this adapter ring. Several different weld failure modes exist for the generator adapter. First, there may be cracks along the top weld leg between the adapter supports and the front adapter ring. Second, there may be cracks at the toe of the welds joining the adapter support bars to the front ring. These cracks appear in the heat-affected zone of the welds and propagate into the front adapter ring of the generator. The third failure mode is radial cracks between the end ring of the generator adapter and the stator housing. This type of crack most likely occurs after the support welds have failed. After the support welds have failed, the cracks at the toe of the support bars propagate into the ring and create a stress riser.
SOLUTION:
Caterpillar is redesigning the current product and is also working on a solution that will address the existing units in the field. At this time, it is NOT recommended to immediately replace cracked generator stators, nor is it recommended to re-weld the cracked adapters as a field repair. Rather, a crack observation and evaluation process should be established for each individual case. It is anticipated that the first recognizable cracks on suspect generators (cracks size of 0.25" and larger) may appear as early as 300 hours. If any of the above-described cracks are found, the servicing dealer should contact Caterpillar Service. The servicing dealer should also assist in periodic inspection of the cracks in an effort to determine the next action.
Contact (if different from sender): Miro Halicek (770) 233-5877 or Marc Sylvester (770) 233-5630.
COPYRIGHT 2002 CATERPILLAR
ALL RIGHTS RESERVED

Have questions with 09009-90440?





Group cross 09009-90440

Back to top