Rating:
Information pump assy, supply Denso
Product
Fuel Injection Pump
Vehicle engine
TRUCK J08E
Engine
J08E
Serial start-end
1702-
Info
Injector Nozzle
HINO
PUMP ASSY, SUPPLY
DA
- THIS CAN BE USED IN PLACE OF 294050-049# AS A SUPPLY.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
HP4 Common Rail Fuel Injection Pump 294050-0940 Compatible For HINO J08E 22100-E0530 22100-E0531 22100-E0532
LCQBXGPU Long lifespan, stable and durable || Enhance power and solve oil leakage || Smooth start-up and improved fuel consumption || Excellent raw materials and advanced technology || HP4 Common Rail Fuel Injection Pump 294050-0940 Compatible For HINO J08E 22100-E0530 22100-E0531 22100-E0532
LCQBXGPU Long lifespan, stable and durable || Enhance power and solve oil leakage || Smooth start-up and improved fuel consumption || Excellent raw materials and advanced technology || HP4 Common Rail Fuel Injection Pump 294050-0940 Compatible For HINO J08E 22100-E0530 22100-E0531 22100-E0532
OCTOT Fuel Injection Pump 294050-0940 294050-0942 22100-E0532 Fits For Hino Engine J08E Series 500
OCTOT Part Name: Fuel Injection Pump || Part Number: 294050-0940 294050-0942 22100-E0532 Note: Please check the fitment carefully before purchase. Or just tell us the part number you need. || Engine Model: J08E || Applicable: Fits For Hino Engine J08E Series 500 || Package included: 1pcs Fuel Injection Pump 294050-0940 294050-0942 22100-E0532
OCTOT Part Name: Fuel Injection Pump || Part Number: 294050-0940 294050-0942 22100-E0532 Note: Please check the fitment carefully before purchase. Or just tell us the part number you need. || Engine Model: J08E || Applicable: Fits For Hino Engine J08E Series 500 || Package included: 1pcs Fuel Injection Pump 294050-0940 294050-0942 22100-E0532
HP4 Common Rail Fuel Injection Pump 294050-0940 22100-E0530 22100-E0531 22100-E0532 294050-0490 294050-0491
HXYAIEOGD Ensure the continuous and stable operation of the engine. || The installation procedure is simple. || Ensure OE number before placing order. || The warranty period is 12 months. || 1 piece jet pump
HXYAIEOGD Ensure the continuous and stable operation of the engine. || The installation procedure is simple. || Ensure OE number before placing order. || The warranty period is 12 months. || 1 piece jet pump
Components :
Scheme #.#:
№
Qty
Part num
Name
Remarks
Manufacture num
000
[01]
29405-00940
PUMP ASSY, SUPPLY
HP4 *
22100-E0532
HINO
Include in ##:
29405-00940
as PUMP ASSY, SUPPLY
Cross reference number
Part num
Firm num
Firm
Name
29405-00940
22100-E053
HINO
PUMP ASSY, SUPPLY
2940500940
22100-E0532
HINO
PUMP ASSY, SUPPLY
Information:
Inspection and Maintenance Agreements
Your Caterpillar dealer can establish an Inspection and Preventive Maintenance Program for your generator set to provide maximum reliability, increased engine and generator life, and minimize expensive repairs. Contact your Caterpillar dealer for details.General Recommendations
Safety
The stop-manual-automatic switch on the cranking panel must be set at STOP position when performing maintenance or repair work on a standby generator set. This prevents the unit from starting if a power failure or voltage drop should occur while working on the unit.To prevent personal injury due to accidental starting of the engine, disconnect the batteries or disable the starting system before doing maintenance or repair work.Lock out all switch gear and automatic transfer switches associated with the generator while performing any generator maintenance or repairs. Make sure no shock hazard exists.Failure to comply could result in personal injury or death.
Always make repairs with the engine stopped and the starting system disabled. When servicing the generator, make sure that switch gear and automatic transfer switches will not present a shock hazard. Lock them out on the generator being serviced.Record Keeping
Maintain a log or record keeping system to document all gauge readings, problems, repairs, and maintenance performed on the equipment.Space Heaters
Moisture is a natural enemy of generators and all electrical equipment. Every effort must be made to keep the generator as dry as possible. Space heaters should be operated inside the generator when it is not in use to maintain the integrity of the generator windings.
Your Caterpillar dealer can establish an Inspection and Preventive Maintenance Program for your generator set to provide maximum reliability, increased engine and generator life, and minimize expensive repairs. Contact your Caterpillar dealer for details.General Recommendations
Safety
The stop-manual-automatic switch on the cranking panel must be set at STOP position when performing maintenance or repair work on a standby generator set. This prevents the unit from starting if a power failure or voltage drop should occur while working on the unit.To prevent personal injury due to accidental starting of the engine, disconnect the batteries or disable the starting system before doing maintenance or repair work.Lock out all switch gear and automatic transfer switches associated with the generator while performing any generator maintenance or repairs. Make sure no shock hazard exists.Failure to comply could result in personal injury or death.
Always make repairs with the engine stopped and the starting system disabled. When servicing the generator, make sure that switch gear and automatic transfer switches will not present a shock hazard. Lock them out on the generator being serviced.Record Keeping
Maintain a log or record keeping system to document all gauge readings, problems, repairs, and maintenance performed on the equipment.Space Heaters
Moisture is a natural enemy of generators and all electrical equipment. Every effort must be made to keep the generator as dry as possible. Space heaters should be operated inside the generator when it is not in use to maintain the integrity of the generator windings.