19100-08394 PUMP ASSY, INJECTI Calibration Data


Rating:
16
Buy PUMP ASSY, INJECTI 19100-08394 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Components :

00.001
PUMP ASSY, INJECTI
NF6,R801
01.002
BODY ASSY, INJECTI
NF6
02.003
COVER, BEARING
DUMMY
01.004
GOVERNOR ASSY, MEC
R801
02.005
LEVER SET
ADJUST L
02.006
COVER ASSY, GOVERN
02.007
COMPENSATOR SUB-AS
01.008
TIMER ASSY, AUTOMA
SA1 -9101
01.008
TIMER ASSY, AUTOMA
9101-
01.009
TIMER ASSY, AUTOMA
SA1
01.010
PUMP ASSY, FUEL FE
KE
01.011
PUMP ASSY, FUEL FE
KE
01.012
PUMP ASSY, FUEL FE
KE
01.013
COUPLING ASSY
SD

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
19100-08394
PUMP ASSY, INJECTI
NF6,R801
22010-6282 HINO
003
[01]
PUMP ASSY, FUEL FE
KE -9102
22570-1430A HINO
003
[01]
PUMP ASSY, FUEL FE
KE22 9102--9803
22570-1500A HINO
003
[01]
PUMP ASSY, FUEL FE
KE 9804-
22570-1730A HINO
004
[01]
VALVE ASSY, OVERFL
1.5-1.8K -9102
22107-1290A HINO
004
[02]
VALVE ASSY, OVERFL
9102-
22107-1430A HINO
005
[02]
WASHER
T1
22847-1940A HINO
006
[01]
COVER, CONTROL RAC
22114-1250A HINO
007
[05]
BOLT, W/WASHER
M6,L16
22815-2410A HINO
009
[01]
BOLT, W/WASHER
M6,L20
22815-1290A HINO
011
[01]
BOLT, W/WASHER
22815-2820A HINO
012
[01]
BODY ASSY, INJECTI
NF6
22110-2541A HINO
013
[01]
COUPLING ASSY
SD
22610-1640A HINO
014
[01]
NUT, TIMER ROUND
22511-1060A HINO
015
[01]
TIMER ASSY, AUTOMA
-9601
22510-2320A HINO
015
[01]
TIMER ASSY, AUTOMA
9601-
22510-2740A HINO
016
[01]
WASHER, COUNTERSUN
T1.5
22867-1320A HINO
017
[01]
KEY, WOODRUFF
W4,H5
22895-1080A HINO
018
[01]
GOVERNOR ASSY, MEC
-9108
018
[01]
GOVERNOR ASSY, MEC
9108--9209
018
[01]
GOVERNOR ASSY, MEC
9209-
22310-4562A HINO
019
[01]
CLIP, CORD
22323-1190A HINO

Include in ##:

19100-08394 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
19100-08394 
22010-6282 
PUMP ASSY, INJECTI

Test Calibration Data:

1910008394 22010-6281A




Information:

Disassembly and Inspection of Starter
Inspection of Starter
(1) Armature coil short-circuit testPlace the armature on the growler. Set an iron piece parallel to the armature, and rotate the armature slowly by hand. If the iron piece is attracted to the coil or vibrates, there is a short-circuit; replace the armature.
Armature coil short-circuit test(2) Armature coil grounding testIf there is continuity between the commutator and shaft (or core), replace the armature.
Armature coil grounding test(3) Measurement of commutator runoutMeasure the commutator runout using a dial gage. If the amount of runout exceeds the limit value, replace the armature. If the commutator surface is rough, refinish the surface with sand paper (#300 to #500). If the surface has ridges due to abrasion, replace the armature since it is not repairable.
Measurement of commutator runout(4) Measurement of commutator outside diameterMeasure the outside diameter of the commutator, and, if the limit is exceeded, replace the armature.
Measurement of commutator outside diameter(5) Measurement of mold depth between segmentsClean the grooves between segments, and measure the mold depths between segments. If the limit value is exceeded, repair. (6) Inspection of armature gearIf the inspection of the armature gear finds abnormal wearing or chipped teeth, replace the armature.
Measurement of mold depth between segments(7) Yoke coil open-circuit testCheck to see if there is continuity between the terminal lead wire and brush (positive). If there is no continuity, there is an open-circuit; replace the yoke assembly.
Yoke coil open-circuit test(8) Yoke coil grounding testCheck to see if there is continuity between the yoke and brush (positive). If there is continuity, the yoke coil is grounded. Check the insulation, and replace the yoke assembly if the problem cannot be corrected.
Yoke coil grounding test(9) Inspection of magnetic switchConduct the following the following continuity tests, and, if there is any problem, replace the magnetic switch.(a) Coil open-circuit testCheck to see if there is continuity between terminal M and ground (case). There should be no continuity between terminal B and ground.(b) Inspection of contact adhesionCheck to make sure there is no continuity between terminal B and terminal M.
Inspection of magnetic switch(10) Measurement of brush lengthMeasure the length of each brush, and, if the limit value is exceeded, replace the brush. If the brush is unevenly worn or has a rough contact surface, refinish with sand paper (#300 to #500).
Measurement of brush length(11) Measurement of brush spring tensionMeasure the installation tension of each brush spring. Read the tension at the moment when the spring detaches from the brush. If the tension value is near the limit value, replace the brush spring.
Measurement of brush spring tension(12) Inspection of brush holders for insulationUsing a tester, check to make sure that there is no continuity between the positive-side brush holder and negative-side brush holder plate. If there is continuity, replace the brush holder.
Inspection of brush holder for insulation(13) Inspection of overrunning clutchMake sure that the pinion shaft rotates smoothly in one direction, and locks in place when it is turned in the opposite direction. If the pinion shaft does not

Have questions with 19100-08394?





Group cross 19100-08394

Back to top