Rating:
Information pump assy, injecti Denso
Product
Fuel Injection Pump
Vehicle engine
INDUSTRIAL 2J
Engine
2J
Serial start-end
8505--8707
Info
Injector Nozzle
093500-1800
Injector nozzle:
0935001800
KIT List:
Part name
Kit1
Kit2
Components :
Scheme #.#:
№
Qty
Part num
Name
Remarks
Manufacture num
000
[01]
19100-01340
PUMP ASSY, INJECTI
22100-78501-71
TOYOTA
Include in ##:
19100-01340
as PUMP ASSY, INJECTI
Cross reference number
Part num
Firm num
Firm
Name
19100-01340
22100-7850
PUMP ASSY, INJECTI
1910001340
22100-78501-71
TOYOTA
PUMP ASSY, INJECTI
Information:
Introduction
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Required Tools
Table 1
Part Number Part Name Qty
- Flat-head screwdriver 1 Replacement Procedure
Illustration 1 g06099930
(1) Connector housing
(2) DCU
(3) Camlock connectors
Locate connector housings (1) on DCU (2). Disconnect the connectors from the DCU.
Illustration 2 g06099944
(1) Connector housing
(3) Camlock connector
(A) Flat-head screwdriver
Use a flat-head screwdriver (A) to pry the tab on the side of connector housing (1) up gently. Pull out on the camlock connector to disengage the locking tab.
Flip connector housing (1) over to the opposite side. Use a flat-head screwdriver (A) to pry the tab on the side of the connector housing up gently. Pull out on the camlock connector to disengage the locking tab.
Illustration 3 g06099938
(1) Connector housing
(3) Camlock connector
Remove camlock connector (3) from connector housing (1).
To install the new camlock connector (3), slide the camlock connector into connector housing (1). Once the camlock is pushed past the locking tabs, the camlock connector will be held in place.
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Required Tools
Table 1
Part Number Part Name Qty
- Flat-head screwdriver 1 Replacement Procedure
Illustration 1 g06099930
(1) Connector housing
(2) DCU
(3) Camlock connectors
Locate connector housings (1) on DCU (2). Disconnect the connectors from the DCU.
Illustration 2 g06099944
(1) Connector housing
(3) Camlock connector
(A) Flat-head screwdriver
Use a flat-head screwdriver (A) to pry the tab on the side of connector housing (1) up gently. Pull out on the camlock connector to disengage the locking tab.
Flip connector housing (1) over to the opposite side. Use a flat-head screwdriver (A) to pry the tab on the side of the connector housing up gently. Pull out on the camlock connector to disengage the locking tab.
Illustration 3 g06099938
(1) Connector housing
(3) Camlock connector
Remove camlock connector (3) from connector housing (1).
To install the new camlock connector (3), slide the camlock connector into connector housing (1). Once the camlock is pushed past the locking tabs, the camlock connector will be held in place.