19100-01340 PUMP ASSY, INJECTI Calibration Data


Rating:
59
Buy PUMP ASSY, INJECTI 19100-01340 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
INDUSTRIAL 2J
Engine
2J
Serial start-end
8505--8707
Info
Injector Nozzle
093500-1800
Injector nozzle: 0935001800

KIT List:

Part name
Kit1
Kit2
Body assy, injecti
Governor assy, mec
Pump assy, fuel fe

Components :

00.001
PUMP ASSY, INJECTI
01.002
BODY ASSY, INJECTI
A4:DRIV.16.8
01.003
GOVERNOR ASSY, MEC
RUV -9011
01.003
GOVERNOR ASSY, MEC
9011-
01.004
PUMP ASSY, FUEL FE
KE

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
19100-01340
PUMP ASSY, INJECTI
22100-78501-71 TOYOTA
001
[01]
BODY ASSY, INJECTI
A4
002
[01]
GOVERNOR ASSY, MEC
RUV
003
[01]
PUMP ASSY, FUEL FE
22110-01620-71 TOYOTA
006
[01]
KEY, WOODRUFF
007
[01]
WASHER, SPRING
T3
008
[01]
NUT, TIMER ROUND
009
[01]
SHAFT, SPLINE
012
[06]
BOLT, W/WASHER
M6,L14
015
[01]
COVER, CONTROL RAC

Include in ##:

19100-01340 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
19100-01340 
22100-7850 
PUMP ASSY, INJECTI
1910001340 
22100-78501-71 
TOYOTA
PUMP ASSY, INJECTI

Test Calibration Data:

1910001340 22100-78501-71A




Information:

Introduction
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Required Tools
Table 1
Part Number Part Name Qty
- Flat-head screwdriver 1 Replacement Procedure
Illustration 1 g06099930
(1) Connector housing
(2) DCU
(3) Camlock connectors
Locate connector housings (1) on DCU (2). Disconnect the connectors from the DCU.
Illustration 2 g06099944
(1) Connector housing
(3) Camlock connector
(A) Flat-head screwdriver
Use a flat-head screwdriver (A) to pry the tab on the side of connector housing (1) up gently. Pull out on the camlock connector to disengage the locking tab.
Flip connector housing (1) over to the opposite side. Use a flat-head screwdriver (A) to pry the tab on the side of the connector housing up gently. Pull out on the camlock connector to disengage the locking tab.
Illustration 3 g06099938
(1) Connector housing
(3) Camlock connector
Remove camlock connector (3) from connector housing (1).
To install the new camlock connector (3), slide the camlock connector into connector housing (1). Once the camlock is pushed past the locking tabs, the camlock connector will be held in place.

Have questions with 19100-01340?





Group cross 19100-01340

Back to top