19100-01180 PUMP ASSY, INJECTI Calibration Data


Rating:
72
Buy PUMP ASSY, INJECTI 19100-01180 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
BUS 8DC8
Engine
8DC8
Serial start-end
8601--8806
Info
Injector Nozzle
093500-3090
Injector nozzle: 0935003090

KIT List:

Part name
Kit1
Kit2
Body assy, injecti
Governor assy, mec
Timer assy, automa
Pump assy, fuel fe

Components :

00.001
PUMP ASSY, INJECTI
P8,R812
01.002
SWITCH KIT, CONTRO
01.003
BODY ASSY, INJECTI
P8
02.004
COVER, BEARING
DUMMY
01.005
GOVERNOR ASSY, MEC
R812
01.006
TIMER ASSY, AUTOMA
SP
01.007
PUMP ASSY, FUEL FE
KE
01.008
COUPLING ASSY
SD

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
19100-01180
PUMP ASSY, INJECTI
P8,R812
ME060335 MITSUBISHI
001
[01]
BODY ASSY, INJECTI
P8
ME702665 MITSUBISHI
002
[01]
GOVERNOR ASSY, MEC
R812
ME703021 MITSUBISHI
003
[01]
TIMER ASSY, AUTOMA
SP
ME702668 MITSUBISHI
004
[01]
PUMP ASSY, FUEL FE
KE
ME702667 MITSUBISHI
005
[01]
COUPLING ASSY
SD
ME702669 MITSUBISHI
011
[01]
WASHER, COPPER PLA
T2
ME702915 MITSUBISHI
012
[08]
BOLT, W/WASHER
M6,L16
ME702916 MITSUBISHI
013
[01]
NUT, TIMER ROUND
ME702917 MITSUBISHI
014
[01]
O-RING
ID27.7
ME702918 MITSUBISHI
015
[01]
WASHER, COUNTERSUN
T1.5ID18
ME702919 MITSUBISHI
016
[01]
KEY, WOODRUFF
W5,H7.5
ME702920 MITSUBISHI
017
[01]
COVER, CONTROL RAC
ME702921 MITSUBISHI
018
[02]
WASHER, COPPER PLA
T1,FOR M16
ME702922 MITSUBISHI
019
[01]
NUT, HEXAGON, W/HO
ME702923 MITSUBISHI
020
[01]
SCREW, ADJUSTING
ME702924 MITSUBISHI
021
[01]
CAP
ME702858 MITSUBISHI
022
[01]
BRACKET, STOP WIRE
ME702672 MITSUBISHI
023
[02]
BOLT, W/WASHER
M8,L14
ME702925 MITSUBISHI
024
[01]
SWITCH KIT, CONTRO
ME702673 MITSUBISHI
027
[01]
SCREW, HOLLOW
M12,L24
ME702926 MITSUBISHI
028
[02]
WASHER, FUEL PIPE
T1.2
ME702927 MITSUBISHI

Include in ##:

19100-01180 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
19100-01180 
ME060335 
PUMP ASSY, INJECTI
1910001180 
ME060335 
MITSUBISHI
PUMP ASSY, INJECTI

Test Calibration Data:

1910001180 ME060335




Information:

Introduction
Do not perform any procedure in the Special Instruction until you read and understand the information that is contained in this document. Caterpillar recommends that no wires thinner than 18 AWG wire are used in the installation of this kit. Caterpillar recommends that some form of circuit protection (that is, circuit breakers) be used to protect the Electronic Control Module (ECM) in cases where there is a direct electrical connection to the battery. Caterpillar recommends that a keyswitch is used to control the power delivery to terminal J1-70 of the ECM to control when the ECM is ON and OFF.Battery power (+) must be supplied to terminals J1-48, 52, 53, and 55 of the ECM and to certain parts where appropriate. A ground/return (-) must be supplied to terminals J1-61, 63, 65, and 69 of the ECM and to certain parts where appropriate. In order to turn on the ECM, power must also be supplied to terminal J1-70 of the ECM. The 160-7689 Connector Plug As connects to the J1 terminal of the ECM.Required Parts
The 356-3348 Kit - Regeneration Switch contains the following parts.
Table 1
Required Parts    
Qty     Part Number     Description    
1     205-5471     Connector    
2     245-7434     Connecting Plug Kit    
1     242-3282     LED Lamp As    
1     284-3623     Rocker Switch    
1     327-6999     Rocker Switch    
1     332-1064     Illuminated Plug    
1     102-8802     Receptacle Kit    
1     372-6047     Indicator    
4     112-9611     Blade Terminal    
1     155-2274     Connecting Plug Kit    Installing the Red LED Lamp (Regeneration Disable Lamp)
Illustration 1 g02402796
242-3282 Led Lamp As Use 155-2269 Connector Plug As as a mating connector. 155-2269 Connector Plug As is not included in the kit. Also, 102-8802 Receptacle Kit contains 3E-3364 Receptacle and 3E-3365 Receptacle Lock Wedge .
Insert the red (power) wire from the 242-3282 LED Lamp As into terminal 1 of 3E-3364 Receptacle .
Insert the black (ground) wire from the LED lamp into terminal 2 of the receptacle.
Insert 3E-3365 Receptacle Lock Wedge is the receptacle.
Connect terminal 1 of the receptacle to terminal 13 of 160-7689 Connector Plug As .
Connect terminal 2 of the receptacle to the ground/return (-).Installing the Illuminated Plug (Regeneration Lamp)
Illustration 2 g02402326
332-1064 Illuminated Plug The terminal designations can be found on the sides of 332-1064 Illuminated Plug and 205-5471 Connector .
Connect terminal 1A of the connector to the battery power (+).
Connect terminal 2A of the connector to the battery power (+).
Connect terminal 1B of the connector to terminal 30 of the plug.
Connect terminal 2B of the connector to terminal 31 of the plug.
Crimp the 112-9611 Blade Terminal onto the wires necessary to create the connections described in the previous steps.
Insert the blade terminals into the appropriate terminal locations of the connector.
Connect the plug to the connector. The plug and the connector are mating connectors.Installing

Have questions with 19100-01180?





Group cross 19100-01180

Back to top