19000-09461 PUMP ASSY, INJECTI Calibration Data


Rating:
16
Buy PUMP ASSY, INJECTI 19000-09461 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Components :

00.001
PUMP ASSY, INJECTI
A6,R811
01.002
BODY ASSY, INJECTI
A6
02.003
COVER, BEARING
DUMMY
01.004
GOVERNOR ASSY, MEC
R811
01.005
TIMER ASSY, AUTOMA
SA/2SP
01.006
PUMP ASSY, FUEL FE
KE
01.007
COUPLING ASSY
SP

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
19000-09461
PUMP ASSY, INJECTI
A6,R811
22090-1251 HINO
005
[01]
BODY ASSY, INJECTI
A6
22110-1860A HINO
006
[01]
GOVERNOR ASSY, MEC
22310-2540A HINO
007
[06]
BOLT, W/WASHER
M6,L14
22815-1620A HINO
008
[01]
BOLT, HEXAGON
M8,L18 -8604
22815-1630A HINO
008
[01]
BOLT, W/WASHER
M8,L18 8604-
22815-2820A HINO
010
[01]
COVER, CONTROL RAC
22114-1050A HINO
011
[01]
TIMER ASSY, AUTOMA
012
[01]
NUT, TIMER ROUND
22511-1070A HINO
013
[01]
KEY, WOODRUFF
T3.985
22895-1010A HINO
014
[01]
WASHER, SPRING
T3.5
22877-1620A HINO
015
[01]
PUMP ASSY, FUEL FE
KE22
22570-1250A HINO
017
[01]
COUPLING ASSY
SP
22610-1300A HINO
018
[01]
VALVE ASSY, OVERFL
1.5-1.8K
22107-1090A HINO
020
[02]
WASHER
T1
22847-1940A HINO

Include in ##:

19000-09461 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
19000-09461 
22090-1251 
PUMP ASSY, INJECTI

Test Calibration Data:

1900009460 22090-1251




Information:

Manual Fuel Shutoff Lever
A manual shutdown lever is provided to override the governor control of the engine. The manual shutoff solenoid override lever is located on the side of the fuel pump. This shutdown will only move the fuel control linkage to the FUEL-OFF position. It does not shut off the air inlet. Shutoff Solenoid Override
The manual shutoff solenoid override lever is located on the side of the electronic governor. The engine can be shut OFF by rotating and holding the manual shutoff lever in the counterclockwise (CCW) direction. Rotating and holding the manual shutoff lever in the clockwise (CW) direction overrides the shutoff solenoid. The lever is spring loaded and will return to the neutral position when released.If the solenoid has been disabled, the engine cannot be shut OFF from inside the cab. The engine can be shut OFF by using the manual shutoff lever as an emergency shutoff lever.
DO NOT operate the engine without the rack actuator solenoid (BTM) in place and with the fuel shutoff solenoid disabled. Excessive engine speed (overspeed) may result.

Have questions with 19000-09461?





Group cross 19000-09461

Back to top