19000-08244 PUMP ASSY, INJECTI Calibration Data


Rating:
41
Buy PUMP ASSY, INJECTI 19000-08244 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Components :

00.001
PUMP ASSY, INJECTI
A6,R801 -9308
00.001
PUMP ASSY, INJECTI
A6,R801 9309-
01.002
SWITCH KIT, CONTRO
01.003
BODY ASSY, INJECTI
A6
01.004
BODY ASSY, INJECTI
A6
01.005
GOVERNOR ASSY, MEC
R801
01.006
TIMER ASSY, AUTOMA
SCZ -8107
01.006
TIMER ASSY, AUTOMA
SCZ 8107-
01.007
PUMP ASSY, FUEL FE
KE

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
PUMP ASSY, INJECTI
A6,R801 -9308
ME035567 MITSUBISHI
000
[01]
19000-08244
PUMP ASSY, INJECTI
A6,R801 9309-
ME035567 MITSUBISHI
005
[01]
BODY ASSY, INJECTI
A6 -9207
ME702012 MITSUBISHI
005
[01]
BODY ASSY, INJECTI
A6 9207-
ME736047 MITSUBISHI
006
[01]
GOVERNOR ASSY, MEC
R801
ME702013 MITSUBISHI
007
[01]
COVER, CONTROL RAC
ME702034 MITSUBISHI
008
[01]
O-RING
ID74.1
MH035502 MITSUBISHI
009
[01]
COVER SUB-ASSY, TI
ME036902 MITSUBISHI
010
[01]
TIMER ASSY, AUTOMA
SCZ
ME036901 MITSUBISHI
011
[04]
NUT, HEXAGON
M10
ME702046 MITSUBISHI
012
[04]
WASHER, SPRING
M10
MC327716 MITSUBISHI
013
[04]
WASHER, STEEL PLAT
FOR M10
MH005068 MITSUBISHI
015
[01]
KEY, WOODRUFF
T3.985
ME702047 MITSUBISHI
016
[01]
WASHER, COUNTERSUN
T1.5ID14
ME702043 MITSUBISHI
017
[01]
NUT, TIMER ROUND
ME702033 MITSUBISHI
019
[01]
PUMP ASSY, FUEL FE
KE
ME035928 MITSUBISHI
020
[01]
BRACKET
ME702036 MITSUBISHI
021
[01]
BOLT, W/WASHER
M8,L18
ME703449 MITSUBISHI
023
[04]
BOLT, W/WASHER
M6,L16
ME702045 MITSUBISHI
024
[02]
BOLT, W/WASHER
M6,L20
ME702041 MITSUBISHI
025
[01]
SWITCH KIT, CONTRO
ME702011 MITSUBISHI
026
[01]
CAP
FOR MAX.SPEED
ME035845 MITSUBISHI
027
[01]
BRACKET
ME702037 MITSUBISHI
028
[01]
NUT, HEXAGON
M10
MF430122 MITSUBISHI
029
[01]
CAP
FOR FULL-LOAD
ME076458 MITSUBISHI

Include in ##:

19000-08244 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
19000-08244 
ME035567 
PUMP ASSY, INJECTI

Test Calibration Data:

1900008240 ME035567
1900008241 ME035567
1900008242 ME035567
1900008243 ME035567
1900008244 ME035567




Information:

Above 0°C (32°F)
1. Place the transmission or other power takeoff attachments in NEUTRAL. For air start systems; check the air supply before starting the engine. There must be 690 kPa (100 psi) air pressure available.2. Move governor control lever (throttle) or depress the accelerator to half engine speed position.3. Turn the battery disconnect switch (if equipped) to the ON position. 4. Push the air start knob (1) IN, or ... ... turn the start switch (2) for marine, industrial and generator set engines or ... ... turn the start switch (3) for machines (vehicles) to the START position.
Do not crank the engine for more than 30 seconds. Allow 2 minutes for the starter to cool before cranking again. If oil pressure does not rise within 15 seconds after the engine starts, stop the engine and make necessary corrections.
5. Release the start switch or air start knob when the engine starts.6. Do not apply load to the engine or increase engine speed until oil pressure and all temperature gauges reach operating temperature. Check all gauges during the warm-up period.Below 0°C (32°F)
Ether is poisonous and flammable.Do not store replacement cylinders in living areas or in the operator's compartment.Do not smoke while changing ether cylinders.Use ether only in well ventilated areas.Use it with care to avoid fires.Avoid breathing of the vapors or repeated contact of ether with skin.Do not puncture or burn cylinders.Discard cylinders in a safe place.Keep ether container away from heat, sparks, open flame, or open sunlight. It may explode.Do not store replacement cylinders at temperatures above 49°C (120°F).Do not use cylinders in environments above 93°C (200°F).
1. Depress ether switch and hold for 3 seconds, then release. For air start system; check the air supply before starting the engine. There must be 690 kPa (100 psi) air pressure available.2. Push the air start knob IN or turn the start switch for engines, or turn the start switch for machines (vehicles) to the START position.3. Begin cranking the engine, and depress ether switch and hold for 3 seconds then release. Additional injections of ether may be required to start and/or achieve low idle speed.4. Operate the engine at low speed and/or load until all systems reach operating temperatures. Check all gauges during the warmup period.
Do not use excessive starting fluid during starting or after the engine is running. Do not crank the engine for more than 30 seconds. Allow 2 minutes for the starter motor to cool before cranking again.If oil pressure does not rise within 15 seconds after the engine starts, stop the engine and make necessary corrections.
Turn the battery disconnect switch (if equipped) OFF after the engine is stopped to prevent battery discharge while starter motor is cooling.For starting below -18°C (0°F), use of optional cold weather starting aids are recommended. A coolant heater or extra battery capacity may be required.For temperatures below -23°C (-10°F), consult your Caterpillar dealer or refer to the "Cold Weather Operation Guide," Form SEBU5338, available from your Caterpillar dealer.

Have questions with 19000-08244?





Group cross 19000-08244

Back to top