19000-07500 PUMP ASSY, INJECTI Calibration Data


Rating:
31
Buy PUMP ASSY, INJECTI 19000-07500 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
INDUSTRIAL DM100
Engine
DM100
Serial start-end
7701--8801
Info
Injector Nozzle
093500-0800
Injector nozzle: 0935000800

KIT List:

Part name
Kit1
Kit2
Body assy, injecti
Governor assy, mec
Pump assy, fuel fe

Components :

00.001
PUMP ASSY, INJECTI
A6,RSV
01.002
BODY ASSY, INJECTI
A6
01.003
GOVERNOR ASSY, MEC
01.004
PUMP ASSY, FUEL FE
KE
01.005
COUPLING ASSY
SP

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
19000-07500
PUMP ASSY, INJECTI
A6,RSV
22030-1450 HINO
006
[01]
BODY ASSY, INJECTI
A6
007
[01]
GOVERNOR ASSY, MEC
RSV
008
[06]
BOLT, W/WASHER
M6,L16
22815-1380A HINO
009
[01]
BOLT, W/WASHER
M8,L22
22815-1190A HINO
011
[01]
PUMP ASSY, FUEL FE
KE
22570-1200 HINO
012
[01]
COUPLING ASSY
SP
013
[01]
COVER, CONTROL RAC
22114-1130A HINO
014
[01]
NUT, TIMER ROUND
22353-1050A HINO
015
[01]
WASHER, SPRING
ID12.2
22873-1310A HINO
016
[01]
KEY, WOODRUFF
22891-1040A HINO
017
[01]
COVER, PRIMING PUM
6 053 1552 60 HINO

Include in ##:

19000-07500 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
19000-07500 
22030-1450 
PUMP ASSY, INJECTI
1900007500 
22030-1450 
HINO
PUMP ASSY, INJECTI

Test Calibration Data:

1900007500 22030-1450




Information:

Clean and Inspect
Before working inside the generator, make sure that the starter motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator:1. The regulator terminal strip2. The excitation transformer terminal strip (self-excited generator only).Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.An electrical shock can be received from the regulator capacitor (C1) when the engine-generator is not in operation. To avoid possible injury, discharge the stored charge using an 100 ohm resistor across C1 terminals.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
If Moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check that all circuit boards are fully plugged in their sockets. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required. Refer to the "Electric Set Generator Service Manual" for testing and adjusting or disassembly and assembly procedures.Space Heaters
The SR4 generator can operate in high humidity conditions without problems. However, problems can occur when the generator is idle and the surrounding air is warmer than the generator. Moisture can form on the windings and result in poor performance and even result in damage to the windings. Whenever the generator is not in use, insure that the space heaters are in operation.An external source of either 115 or 230 (200 v at 50 Hz) volts A.C. is required to operate the space heaters. Space Heater Connection to External Source H1, H2, H3, H4. Terminal Strip Terminals If 115 VAC source is available, connect both heaters in parallel across the source (L1-L2). If 230 VAC source is available, connect both heaters in

Have questions with 19000-07500?





Group cross 19000-07500

Back to top