Rating:
Information pump assy, injecti Denso
Product
Fuel Injection Pump
Vehicle engine
TRUCK 4D5T
Engine
4D5T
Serial start-end
8704-
Info
Injector Nozzle
093500-3460
Manufacture:
MD111577 MITSUBISHI
Dim 1
3.2-3.4
Dim 2
5.8-6.0
Dim 3
0.75-0.95
Dim 4
Dim 5
Dim 6
Information
Injector nozzle:
0935003460
KIT List:
Part name
Kit1
Kit2
Components :
Scheme #.#:
№
Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09600-03360
PUMP ASSY, INJECTI
MD111577
MITSUBISHI
Include in ##:
09600-03360
as PUMP ASSY, INJECTI
Cross reference number
Part num
Firm num
Firm
Name
09600-03360
MD111577
PUMP ASSY, INJECTI
0960003360
MD111577
MITSUBISHI
PUMP ASSY, INJECTI
Information:
Logged Events
When an event is activated, information about the event is logged into permanent memory for the Electronic Control Module. The CDL can then request this information from the ECM. The CDL will display the following information for each logged event. Up to twenty five different events can be logged. Events are not automatically erased.
EID
FMI
Description of the event
Number of occurrences
The first time of occurrence
The last time of occurrenceEvents may be cleared from the memory of the ECM in order to use the CDL. Logged events can be configured so that a factory password is required to clear the event. Table 1 references the Event Codes that can be seen in order to use the Diesel Particulate Filter Monitor System.
Table 1
EID     Description     Security Level    
194     Warning for the High Exhaust Temperature     1    
194     Critical Warning for the High Exhaust Temperature     2    
1049     Warning for the Pressure Inlet for the High Particulate Trap     1    
1049     Critical Warning for the Pressure Inlet for the High Particulate Trap     2    
When an event is activated, information about the event is logged into permanent memory for the Electronic Control Module. The CDL can then request this information from the ECM. The CDL will display the following information for each logged event. Up to twenty five different events can be logged. Events are not automatically erased.
EID
FMI
Description of the event
Number of occurrences
The first time of occurrence
The last time of occurrenceEvents may be cleared from the memory of the ECM in order to use the CDL. Logged events can be configured so that a factory password is required to clear the event. Table 1 references the Event Codes that can be seen in order to use the Diesel Particulate Filter Monitor System.
Table 1
EID     Description     Security Level    
194     Warning for the High Exhaust Temperature     1    
194     Critical Warning for the High Exhaust Temperature     2    
1049     Warning for the Pressure Inlet for the High Particulate Trap     1    
1049     Critical Warning for the Pressure Inlet for the High Particulate Trap     2