09450-01950 PUMP ASSY, INJECTI Calibration Data


Rating:
46
Buy PUMP ASSY, INJECTI 09450-01950 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
INDUSTRIAL BT-O
Engine
BT-O
Serial start-end
8001-
Info
Injector Nozzle
093500-1660
Injector nozzle: 0935001660

Components :

00.001
PUMP ASSY, INJECTI
PFR1M

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
PUMP ASSY, INJECTI
PFR1M
001
[01]
HOUSING SUB-ASSY,
002
[01]
HOLDER, DELIVERY V
-9004
002
[01]
HOLDER, DELIVERY V
9005-
003
[01]
SPRING, DELIVERY V
004
[01]
GASKET, DELIVERY V
D11.8
005
[01]
VALVE SUB-ASSY, IN
006
[01]
ELEMENT SUB-ASSY,
008
[01]
SEAT, SPRING, UPR
009
[01]
SPRING, PUMP PLUNG
010
[01]
SLEEVE, PLUNGER CO
011
[01]
TAPPET SUB-ASSY,IN
011-001
[01]
TAPPET, INJECTION
011-002
[01]
ROLLER, FEED PUMP
011-003
[01]
PIN, INJECTION PUM
012
[01]
RACK ASSY, CONTROL
013
[01]
WASHER, COPPER PLA
T1
014
[01]
SCREW, AIR BLEEDER
015
[01]
SCREW, HOLLOW
016
[02]
WASHER, AIR BLEEDE
T1.6
017
[01]
PIN, INJECTION PUM
-9702
017
[01]
PIN, INJECTION PUM
9702-
018
[01]
SEAT, SPRING, LWR
019
[01]
RING, SNAP
ID27.6
020
[01]
O-RING
ID14.8 -0501
020
[01]
O-RING
ID14.8 0502-
022
[1C]
PLATE, TAPPET ADJU
T0.6
022
[1C]
PLATE, TAPPET ADJU
T0.2
022
[1C]
PLATE, TAPPET ADJU
T0.3
022
[1C]
PLATE, TAPPET ADJU
T0.4
022
[1C]
PLATE, TAPPET ADJU
T0.5
022
[1C]
PLATE, TAPPET ADJU
T0.25
022
[1C]
PLATE, TAPPET ADJU
T0.35
022
[1C]
PLATE, TAPPET ADJU
T0.55
022
[1C]
PLATE, TAPPET ADJU
T0.65

Cross reference number



Part num
Firm num
Firm
Name
09450-01950 
 
PUMP ASSY, INJECTI

Test Calibration Data:

0945001950 KB82330




Information:

System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The thermocouple module has five LED indicators. Four of the LED indicators are "Channel Status" indicators. The "Channel Status" indicators are numbered according to the channel. One of the LED indicators is a "Module Status" indicator. You can recover from the "Channel Status" errors.Diagnostics are displayed on the "Module Status" LED indicator. Operating errors are displayed on the "Module Status" LED indicator. Problems may be detected during powerup or problems may be detected during operation. When an error occurs the module will not communicate with the processor. The channel is disabled and the data is cleared.
Illustration 1 g00563580
Diagram of the LED indicators
Illustration 2 g00563584
Diagram of the thermocouple module
Illustration 3 g00563586
Schematic of the thermocouple moduleFunctional Test
The "Module Status" LED is on. The module is operating normally. Stop.
The "Channel Status" LED is on. The module is operating normally. Stop.
The "Module Status" LED is off. The module is in a fault condition. Proceed to 6.
The "Channel Status" LED is off. The channel is not enabled. This is normal if the sensor is not wired.
The "Channel Status" LED is blinking. The module is in a fault condition. Proceed to 10.
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 7.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Check the LED indicator on the module.
Connect the power supply.
Cycle the power to the module.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 8.
Check the module for a fault.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
To avoid potential damage to the processor, handle all modules by the ends of the carrier or edges of the plastic housing. Skin oil or dirt can corrode metallic surfaces, inhibiting electrical contact.
Disconnect the power supply.
Remove the module from the chassis.Reference: Maintenance Procedure,

Have questions with 09450-01950?





Group cross 09450-01950

Back to top