09450-01720 PUMP ASSY, INJECTI Calibration Data


Rating:
76
Buy PUMP ASSY, INJECTI 09450-01720 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
INDUSTRIAL E70
Engine
E70
Serial start-end
8001-
Info
Injector Nozzle
093500-1930
Injector nozzle: 0935001930

Components :

00.001
PUMP ASSY, INJECTI
PFR1M

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
PUMP ASSY, INJECTI
PFR1M
14971-51012 KUBOTA
001
[01]
HOUSING SUB-ASSY,
-9710
14287-51081 KUBOTA
001
[01]
HOUSING SUB-ASSY,
9710-
002
[01]
HOLDER, DELIVERY V
-9004
15601-51221 KUBOTA
002
[01]
HOLDER, DELIVERY V
9005-
003
[01]
SPRING, DELIVERY V
15221-51231 KUBOTA
004
[01]
GASKET, DELIVERY V
D11.8
11420-51241 KUBOTA
005
[01]
VALVE SUB-ASSY, IN
MK: -
15221-51031 KUBOTA
006
[01]
ELEMENT SUB-ASSY,
MK:1790
14911-51051 KUBOTA
008
[01]
SEAT, SPRING, UPR
15221-51271 KUBOTA
009
[01]
SPRING, PUMP PLUNG
L36.3
15221-51281 KUBOTA
010
[01]
SLEEVE, PLUNGER CO
15221-51382 KUBOTA
011
[01]
TAPPET SUB-ASSY,IN
15221-51071 KUBOTA
011-001
[01]
TAPPET, INJECTION
15021-51990 KUBOTA
011-002
[01]
PIN, INJECTION PUM
15021-51970 KUBOTA
011-003
[01]
ROLLER, FEED PUMP
15109-52931 KUBOTA
012
[01]
RACK ASSY, CONTROL
14911-51061 KUBOTA
015
[01]
SCREW, HOLLOW
M10
14911-51321 KUBOTA
016
[02]
WASHER, AIR BLEEDE
T1.6ID12
15221-96651 KUBOTA
017
[01]
PIN, INJECTION PUM
-9702
15221-51251 KUBOTA
017
[01]
PIN, INJECTION PUM
9702-
018
[01]
SEAT, SPRING, LWR
15021-51291 KUBOTA
019
[01]
RING, SNAP
ID27.6
14911-51431 KUBOTA
020
[01]
O-RING
ID14.8 -0501
14611-51201 KUBOTA
020
[01]
O-RING
ID14.8 0502-
022
[1C]
PLATE, TAPPET ADJU
T0.6
14109-51301 KUBOTA
022
[1C]
PLATE, TAPPET ADJU
T0.2
022
[1C]
PLATE, TAPPET ADJU
T0.3
022
[1C]
PLATE, TAPPET ADJU
T0.4
15221-51491 KUBOTA
022
[1C]
PLATE, TAPPET ADJU
T0.5
022
[1C]
PLATE, TAPPET ADJU
T0.25
022
[1C]
PLATE, TAPPET ADJU
T0.35
022
[1C]
PLATE, TAPPET ADJU
T0.45
022
[1C]
PLATE, TAPPET ADJU
T0.55
022
[1C]
PLATE, TAPPET ADJU
T0.65

Cross reference number



Part num
Firm num
Firm
Name
09450-01720 
 
PUMP ASSY, INJECTI
0945001720 
14971-51012 
KUBOTA
PUMP ASSY, INJECTI

Test Calibration Data:

0945001720 14971-51011




Information:

System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.When the red LED is illuminated, there is a fatal error. A fatal error indicates that the processor is not communicating.
Illustration 1 g00563543
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 4.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Test the memory module.
To avoid damage to electronic components, do not remove the processor from the SLC 5/04 Chassis until all power is removed from the power supply.Do not expose memory modules to surfaces or areas that may typically hold an electrostatic charge.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Remove the processor from the chassis.
Remove the memory module.
Install the processor.
Connect the power supply.
Energize the PLC.Reference: Maintenance Procedure, "Memory Module - Replace"The results of the preceding procedure are in the following list:
The "FLT" LED is flashing. Replace the memory module. Refer to Maintenance Procedure, "Memory Module - Replace". Stop.
The "FLT" LED is steady. Install the memory module. Proceed to 4.
Check the line voltage.
Reconnect the power supply.
Measure the line voltage at the terminals.
Verify the voltage of the power supply. The power supply voltage should be measured between 21.0 VDC and 28.0 VDC.The results of the preceding procedure are in the following list:
The line voltage is in the range. Install the processor in another chassis. Verify the diagnostic indicators. The fault is present. Replace the processor. Verify that the repair solves the problem. Refer to Maintenance Procedure, "Processor - Replace".
The line voltage is out of the range. Refer to Troubleshooting, "System Power". Stop.

Have questions with 09450-01720?





Group cross 09450-01720

Back to top