09450-00140 PUMP ASSY, INJECTI Denso Cross


Rating:
78
Buy PUMP ASSY, INJECTI 09450-00140 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
INDUSTRIAL ER80
Engine
ER80
Serial start-end
7411--9602
Info
Injector Nozzle

Components :

00.001
PUMP ASSY, INJECTI
PFR1K

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09450-00140
PUMP ASSY, INJECTI
PFR1K
14381-51012 KUBOTA
001
[01]
HOUSING SUB-ASSY,
005
[01]
HOLDER, DELIVERY V
14109-51221 KUBOTA
009
[01]
SPRING, DELIVERY V
14205-51230 KUBOTA
010
[01]
VALVE SUB-ASSY, IN
MK:50/1
15021-51031 KUBOTA
011
[01]
GASKET, DELIVERY V
15021-51241 KUBOTA
012
[01]
ELEMENT SUB-ASSY,
MK:041-0
14123-51041 KUBOTA
013
[01]
SLEEVE, PLUNGER CO
14109-51390 KUBOTA
014
[01]
SEAT, SPRING, UPR
15221-51271 KUBOTA
015
[01]
SPRING, PUMP PLUNG
14109-51280 KUBOTA
016
[01]
SEAT, SPRING, LWR
15021-51291 KUBOTA
017
[1C]
PLATE, TAPPET ADJU
T0.6
14109-51301 KUBOTA
017
[1C]
PLATE, TAPPET ADJU
T0.2
017
[1C]
PLATE, TAPPET ADJU
T0.3
017
[1C]
PLATE, TAPPET ADJU
T0.4
15221-51491 KUBOTA
017
[1C]
PLATE, TAPPET ADJU
T0.5
017
[1C]
PLATE, TAPPET ADJU
T0.25
017
[1C]
PLATE, TAPPET ADJU
T0.35
017
[1C]
PLATE, TAPPET ADJU
T0.55
017
[1C]
PLATE, TAPPET ADJU
T0.65
018
[01]
TAPPET SUB-ASSY,IN
15221-51071 KUBOTA
018-001
[01]
TAPPET, INJECTION
15021-51990 KUBOTA
018-002
[01]
PIN, INJECTION PUM
15021-51970 KUBOTA
018-003
[01]
ROLLER, FEED PUMP
15109-52931 KUBOTA
019
[01]
PIN, INJECTION PUM
14109-51250 KUBOTA
020
[01]
RING, CLAMP
021
[01]
RACK ASSY, CONTROL
14109-51261 KUBOTA
022
[01]
SCREW, HOLLOW
15221-51321 KUBOTA
023
[01]
WASHER, COPPER PLA
T1
15221-96661 KUBOTA
024
[01]
SCREW, AIR BLEEDER
15221-51351 KUBOTA
025
[02]
WASHER, AIR BLEEDE
T1.6ID12
15221-96651 KUBOTA

Include in ##:

09450-00140 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
09450-00140 
14381-5101 
PUMP ASSY, INJECTI
0945000140 
14381-51012 
KUBOTA
PUMP ASSY, INJECTI




Information:

Clean and Inspect
Before working inside the generator, make sure that the starter motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator:1. The regulator terminal strip2. The excitation transformer terminal strip (self-excited generator only).Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.An electrical shock can be received from the regulator capacitor (C1) when the engine-generator is not in operation. To avoid possible injury, discharge the stored charge using an 100 ohm resistor across C1 terminals.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
If Moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check that all circuit boards are fully plugged in their sockets. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required. Refer to the "Electric Set Generator Service Manual" for testing and adjusting or disassembly and assembly procedures.Space Heaters
The SR4 generator can operate in high humidity conditions without problems. However, problems can occur when the generator is idle and the surrounding air is warmer than the generator. Moisture can form on the windings and result in poor performance and even result in damage to the windings. Whenever the generator is not in use, insure that the space heaters are in operation.An external source of either 115 or 230 (200 v at 50 Hz) volts A.C. is required to operate the space heaters. Space Heater Connection to External Source H1, H2, H3, H4. Terminal Strip Terminals If 115 VAC source is available, connect both heaters in parallel across the source (L1-L2). If 230 VAC source is available, connect both heaters in

Have questions with 09450-00140?





Group cross 09450-00140

Back to top