09300-07000 PUMP ASSY, INJECTI Calibration Data


Rating:
56
Buy PUMP ASSY, INJECTI 09300-07000 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
TRUCK 4D33
Engine
4D33
Serial start-end
Info
Injector Nozzle
093500-6040
Injector nozzle: 0935006040

KIT List:

Part name
Kit1
Kit2
Governor assy, mec
Pump assy, fuel fe
Body assy, injecti

Components :

00.001
PUMP ASSY, INJECTI
-1610
00.001
PUMP ASSY, INJECTI
1610-
01.002
GOVERNOR ASSY, MEC
R901
02.003
LEVER SET
ADJUST L
01.004
TIMER ASSY, AUTOMA
01.005
TIMER ASSY, AUTOMA
01.006
PUMP ASSY, FUEL FE
KS
01.007
BODY ASSY, INJECTI
NB4

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09300-07000
PUMP ASSY, INJECTI
-1610
ME230525 MITSUBISHI
000
[01]
PUMP ASSY, INJECTI
1610-
ME231295 MITSUBISHI
003
[01]
BODY ASSY, INJECTI
NB4
ME736900 MITSUBISHI
004
[01]
GOVERNOR ASSY, MEC
R901
005
[01]
TIMER ASSY, AUTOMA
-1610
ME743978 MITSUBISHI
005
[01]
TIMER ASSY, AUTOMA
1610-
ME761050 MITSUBISHI
006
[01]
PUMP ASSY, FUEL FE
ME743982 MITSUBISHI
007
[01]
COVER SUB-ASSY, TI
ME743445 MITSUBISHI
008
[01]
O-RING
ID79.5
ME736557 MITSUBISHI
009
[01]
KEY, WOODRUFF
W5,H7.5
ME702920 MITSUBISHI
010
[01]
NUT, TIMER ROUND
ME736909 MITSUBISHI
011
[01]
WASHER, COPPER PLA
T1.5
ME039681 MITSUBISHI
012
[01]
COVER, CONTROL RAC
ME736558 MITSUBISHI
013
[01]
CAP
FOR MAX.SPEED
ME035845 MITSUBISHI
014
[04]
WASHER, STEEL PLAT
FOR M10
MH005068 MITSUBISHI
015
[04]
WASHER, SPRING
M10
MC327716 MITSUBISHI
016
[04]
NUT, HEXAGON
M10
MF430122 MITSUBISHI
017
[02]
BOLT, W/WASHER
M8,L14
ME728977 MITSUBISHI
018
[01]
BOLT, W/WASHER
M8,L22
ME728980 MITSUBISHI
019
[01]
BOLT, W/WASHER
M8,L20
ME728979 MITSUBISHI
020
[04]
BOLT, W/WASHER
M8,L16
ME728978 MITSUBISHI
023
[01]
CAP
FOR FULL-LOAD
ME076458 MITSUBISHI

Include in ##:

09300-07000 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
09300-07000 
ME230525 
PUMP ASSY, INJECTI
0930007000 
ME230525 
MITSUBISHI
PUMP ASSY, INJECTI
0930007000 
ME231295 
MITSUBISHI
PUMP ASSY, INJECTI

Test Calibration Data:

0930007000




Information:

Introduction
The following Special Instruction is for the repair of Long Fiber Injection (LFI) components with Polymethyl Methacrylate (PMMA) surfaces on the machines listed above. The Surfaces consist of four parts: cover layer, color layer, carrier layer, and backing foam. Refer to "Repair Procedure" for the proper procedure to repair these surfaces.Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Safety Section
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
When removing a major component or attachment, ensure that it is properly blocked or secured before removing mounting hardware. An assembly that is disconnected without proper blocking may shift or fall, resulting in serious injury or death of personnel or machine damage.
Personal injury can result from improper handling of chemicals.Make sure you use all the necessary protective equipment required to do the job.Make sure that you read and understand all directions and hazards described on the labels and material safety data sheet of any chemical that is used.Observe all safety precautions recommended by the chemical manufacturer for handling, storage, and disposal of chemicals.
Climbing equipment may be required to access this service point. Refer to the Operation and Maintenance Manual, "Mounting and Dismounting" topic for safety information.
Before servicing/performing maintenance on the machine, electrical power must be physically disconnected; battery plugs must be disconnected from the batteries, or the trailing cable must be unplugged, and warning tags and padlocks shall be applied by a certified electrician. Certified electricians shall perform or direct any electrical work, including any energized testing, repair work in controllers, motors, or other approved compartments, and shall insure that all compartments are properly closed and inspected prior to re-energization. All applicable lock out and tag out procedures must be followed.
Observe the safe working load limits of all lifting and blocking devices and keep a safe distance from suspended/blocked loads. Personnel may be seriously injured or killed by falling loads.
Required Parts
The LFI component PMMA surface characteristics are as follows
Cover Layer
Gloss
Scratch resistance
Weather resistance
Color Layer
Coloring
Ultraviolet resistance
Carrier Layer
Adhesion to backing foam
Heat deformation resistance
Backing Foam
Strength
Stability
Impact resistance
Heat deformation resistanceRepair Procedure
Illustration 1 g06509785
Simulated punch hole
Illustration 2 g06509787
Location to grind off backside
Grind material off from backside
Illustration 3 g06509788
Fiberglass mat and plastic filler
Place fiberglass mat and place plastic filler on backside
Illustration 4 g06509791
Location to grind off exterior side
Grind material off from exterior side
Illustration 5 g06509792
Location to add filler on exterior side
Fill hole on exterior side with plastic filler

Have questions with 09300-07000?





Group cross 09300-07000

Back to top