09210-03330 PUMP ASSY, FUEL FE Denso Cross


Rating:
16
Buy PUMP ASSY, FUEL FE 09210-03330 genuine, new aftermarket engine parts with delivery

Information pump assy, fuel fe Denso

KIT List:

Part name
Kit1
Kit2
Pump assy, fuel fe
Pump assy, fuel fe
Pump assy, fuel fe
Pump assy, fuel fe

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09210-03330
PUMP ASSY, FUEL FE
002
[01]
HOUSING SUB-ASSY,
002-001
[01]
ROD, FEED PUMP PUS
002-002
[01]
SEAL, OIL
003
[02]
VALVE, FEED PUMP C
004
[02]
SPRING, FEED PUMP
005
[02]
GASKET, CHECK VALV
ID16 COPPER
006
[01]
SUPPORT, VALVE
007
[01]
PUMP SUB-ASSY, PRI
ALUMINUM
008
[01]
PISTON, FEED PUMP
BLUE
009
[01]
TAPPET, FEED PUMP
010
[01]
ROLLER, FEED PUMP
011
[01]
PIN, FEED PUMP TAP
012
[02]
BLOCK, FEED PUMP T
013
[01]
SPRING, FEED PUMP
014
[01]
PLUG, FEED PUMP PI
015
[01]
FILTER, FEED PUMP
016
[01]
SCREW, FUEL PIPE H
M14,L26
017
[04]
WASHER, FUEL PIPE
T1.2
018
[01]
WASHER, COPPER PLA
T1
020
[01]
RING, SNAP
ID28
022
[01]
SCREW, HOLLOW
M14,L10
024
[01]
NIPPLE, SWIVELING

Include in ##:

Cross reference number



Part num
Firm num
Firm
Name
09210-03330 
 
PUMP ASSY, FUEL FE




Information:

Procedure for Pressure Lubrication
1. Clean the tank of the 1P540 Flow Checking Tool Group thoroughly, and set the pressure regulator to 35 5 psi (240 35 kPa).
Air pressure should not be more than 50 psi (345 kPa) at any time.
2. Put approximately one gallon of engine oil in the tank.
PRESSURE LUBRICATION (Using the 1P540 Flow Checking Tool Group)3. Connect the tools to the engine as shown. The tap shown is connected to the main oil passage.4. Add air pressure to the tank, with the regulator set at 35 5 psi (240 35 kPa). Although the tank does have a hand pump, it is difficult to get enough air pressure to do the job with the hand pump. Therefore, use of shop air is recommended.5. Let the one gallon of engine oil flow into the oil passage under pressure.When filling the crankcase, put in one gallon of oil less than the recommendation in the Lubrication and Maintenance Guides, if engine has received this pressure lubrication application. Also if the engine is not going to be used for a long time, do the above procedure again before the first starting.If shop air is not available for charging the tank, the hand pump may be used to get the minimum required pressure.
Do not use the same 1P540 Flow Checking Tool Group for both "pressure lubrication application" and for checking fuel flow. Incorrect cleaning is probable if the tool is used for both fuel and lube oil. Even a minute amount of dirt in the fuel system can cause fuel nozzle failure.
Dynamometer Test Precaution
To avoid possible engine damage while testing on a dynamometer, the thermostats must be installed and the shunt line connected as shown.
SHUNT LINE CONNECTED TO ENGINEInitial Operation After Engine Reconditioning
The quality of oil control components used in Caterpillar engines is such that, following engine reconditioning (with Caterpillar Service Parts), only an initial operational check is necessary before continued operation in normal service.The purpose of this initial operational check is to: insure that the engine has been assembled properly; determine if proper pressures and temperatures are maintained in the lubrication, cooling and fuel systems; correct any leaks; perform necessary adjustments (such as valve clearance, governor high and low idle speeds, etc.); check the power setting of the engine.To provide a safe, uniform initial operational check, the following procedure is recommended:1. Motor engine at cranking speed until oil pressure is observed.2. Operate engine for 10 minutes at low idle.3. Operate engine for 15 minutes at half-load and 3/4rated speed.4. Operate engine for 30 minutes at rated load and speed.

Have questions with 09210-03330?