Information pump assy, fuel fe Denso
KIT List:
Part name
Kit1
Kit2
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$165.33
29 Jul 2024
CN: David-Store
Water Pump 092100-1870 15896582 0921001870 Fits for CLG908D 41R18N 41R18T P185WIR XP185WIR
CNCJNXW ◆Part Name◆:Water Pump || ◆Part Number◆:092100-1870 15896582 0921001870 || ◆Application◆:Fits for CLG908D 41R18N 41R18T P185WIR XP185WIR || NOTE Please check the part number before purchase, do not only look at the appearance of the purchase, check the part number is the best way to reduce the error rate. If you are not clear, please contact us, we are very happy to serve you! || Worth Choice Our product quality is reliable, after-sales guarantee! If you have any questions, please contact us in time, communication is the best way to solve the problem!
CNCJNXW ◆Part Name◆:Water Pump || ◆Part Number◆:092100-1870 15896582 0921001870 || ◆Application◆:Fits for CLG908D 41R18N 41R18T P185WIR XP185WIR || NOTE Please check the part number before purchase, do not only look at the appearance of the purchase, check the part number is the best way to reduce the error rate. If you are not clear, please contact us, we are very happy to serve you! || Worth Choice Our product quality is reliable, after-sales guarantee! If you have any questions, please contact us in time, communication is the best way to solve the problem!
$152.10
28 Feb 2024
CN: UOYETIB-US
UOYETIB Water Pump Electric Control 092100-1870 for Liugong CLG908D Excavator Yanmar 4TNV98T Engine
UOYETIB Part Name: Water Pump || Part Number: 092100-1870 || Application: for Liugong CLG908D Excavator Yanmar 4TNV98T Engine || Model: CLG908D 4TNV98T || Application information provided is for reference only. Please make sure to match the exact part numbers between this part and the part that you are replacing. Ask your mechanics or us to make sure it matches exactly in case of doubt before purchasing.
UOYETIB Part Name: Water Pump || Part Number: 092100-1870 || Application: for Liugong CLG908D Excavator Yanmar 4TNV98T Engine || Model: CLG908D 4TNV98T || Application information provided is for reference only. Please make sure to match the exact part numbers between this part and the part that you are replacing. Ask your mechanics or us to make sure it matches exactly in case of doubt before purchasing.
$151.50
18 Jul 2023
CN: RobortStore
Wieoncke Water Pump Electric Control 092100-1870 for Liugong CLG908D Excavator Yanmar 4TNV98T Engine
Wieoncke Part Name: Water Pump || Part Number: 092100-1870 || Application: for Liugong CLG908D Excavator Yanmar 4TNV98T Engine || Model: CLG908D 4TNV98T || Application information provided is for reference only. Please make sure to match the exact part numbers between this part and the part that you are replacing. Ask your mechanics or us to make sure it matches exactly in case of doubt before purchasing.
Wieoncke Part Name: Water Pump || Part Number: 092100-1870 || Application: for Liugong CLG908D Excavator Yanmar 4TNV98T Engine || Model: CLG908D 4TNV98T || Application information provided is for reference only. Please make sure to match the exact part numbers between this part and the part that you are replacing. Ask your mechanics or us to make sure it matches exactly in case of doubt before purchasing.
Scheme #.#:
№
Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09210-01870
PUMP ASSY, FUEL FE
KS
000
[01]
09210-01870
PUMP ASSY, FUEL FE
KS
000
[01]
09210-01870
PUMP ASSY, FUEL FE
KS
Include in ##:
Cross reference number
Part num
Firm num
Firm
Name
09210-01870
PUMP ASSY, FUEL FE
Information:
To Stop the Engine
A spring loaded stop control is usually situated near the normal engine controls and it is only necessary to pull out the stop control until the engine ceases to rotate. Ensure the engine movement has completely stopped before returning the control to the normal running condition. Turn the starter switch to the "O" position.Some engines may have an electric solenoid stop control on the fuel injection pump operated by a switch on the control panel.Cold Starting Aid; Using the Starting Aid
C1 1. Off Position2. Run Position3. Heat Position4. Heat and Start PositionTo start the engine, proceed as follows:-Ensure engine stop control is pushed fully home.Turn starter switch (Fig. C.1) to the "H" position and hold it there for fifteen to twenty seconds.With the accelerator in the fully open position, turn the starter switch to the "HS" position thereby engaging the starter motor.If the engine does not start within fifteen seconds, return the switch to the "H" position for ten seconds and then re-engage the starter motor by switching to the "HS" position.As soon as the engine starts, the switch should be returned to the "R" position.Earlier Heat Start Switch
C2 1. Off2. Start3. Heat4. Heat and StartThe cold start switch fitted to earlier engines is shown in Fig. C.2.Where this type of switch is used, it is customary to have a separate switch for the electrical circuits and this should be turned on before starting the engine and turned off after stopping the engine.Things to Note
Ensure that the electrical connection to the cold starting aid is correctly made.In the event of difficult starting, check that fuel is reaching the cold starting aid in the induction manifold by unscrewing the inlet fuel connection. If fuel is reaching it satisfactorily, then it may be that the cold starting aid itself is not working correctly. This can be checked by removing the air cleaner and watching the cold starting aid whilst the equipment is used. When the starting switch is turned to the "heat" position, the element should become red hot, and on engagement of the starter motor, ignition of the fuel should take place. The engines are fitted with efficient cold starting equipment and no responsibility can be accepted for any damage caused by unauthorised starting aids.Running In
It is not necessary to gradually run-in a new or factory rebuilt engine and any prolonged light load running during the early life of the engine can in fact prove harmful to the bedding in of piston rings and liners.Full load can be applied on a new or factory rebuilt engine as soon as the engine is used, provided that the engine is first allowed to reach a temperature of at least 140°F (60°C).Preventive Maintenance
Whilst we have given specific periods for preventive maintenance, you should have due regard for the local regulations concerning your vehicle or machine and ensure that the engine is operating within those regulations.The time period for cleaning the oil bath type air cleaner or the renewing of
A spring loaded stop control is usually situated near the normal engine controls and it is only necessary to pull out the stop control until the engine ceases to rotate. Ensure the engine movement has completely stopped before returning the control to the normal running condition. Turn the starter switch to the "O" position.Some engines may have an electric solenoid stop control on the fuel injection pump operated by a switch on the control panel.Cold Starting Aid; Using the Starting Aid
C1 1. Off Position2. Run Position3. Heat Position4. Heat and Start PositionTo start the engine, proceed as follows:-Ensure engine stop control is pushed fully home.Turn starter switch (Fig. C.1) to the "H" position and hold it there for fifteen to twenty seconds.With the accelerator in the fully open position, turn the starter switch to the "HS" position thereby engaging the starter motor.If the engine does not start within fifteen seconds, return the switch to the "H" position for ten seconds and then re-engage the starter motor by switching to the "HS" position.As soon as the engine starts, the switch should be returned to the "R" position.Earlier Heat Start Switch
C2 1. Off2. Start3. Heat4. Heat and StartThe cold start switch fitted to earlier engines is shown in Fig. C.2.Where this type of switch is used, it is customary to have a separate switch for the electrical circuits and this should be turned on before starting the engine and turned off after stopping the engine.Things to Note
Ensure that the electrical connection to the cold starting aid is correctly made.In the event of difficult starting, check that fuel is reaching the cold starting aid in the induction manifold by unscrewing the inlet fuel connection. If fuel is reaching it satisfactorily, then it may be that the cold starting aid itself is not working correctly. This can be checked by removing the air cleaner and watching the cold starting aid whilst the equipment is used. When the starting switch is turned to the "heat" position, the element should become red hot, and on engagement of the starter motor, ignition of the fuel should take place. The engines are fitted with efficient cold starting equipment and no responsibility can be accepted for any damage caused by unauthorised starting aids.Running In
It is not necessary to gradually run-in a new or factory rebuilt engine and any prolonged light load running during the early life of the engine can in fact prove harmful to the bedding in of piston rings and liners.Full load can be applied on a new or factory rebuilt engine as soon as the engine is used, provided that the engine is first allowed to reach a temperature of at least 140°F (60°C).Preventive Maintenance
Whilst we have given specific periods for preventive maintenance, you should have due regard for the local regulations concerning your vehicle or machine and ensure that the engine is operating within those regulations.The time period for cleaning the oil bath type air cleaner or the renewing of