09210-01580 PUMP ASSY, FUEL FE Denso Cross


Rating:
12
Buy PUMP ASSY, FUEL FE 09210-01580 genuine, new aftermarket engine parts with delivery

Information pump assy, fuel fe Denso

KIT List:

Part name
Kit1
Kit2
Pump assy, fuel fe
Pump assy, fuel fe
Pump assy, fuel fe
Pump assy, fuel fe
Pump assy, fuel fe

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09210-01580
PUMP ASSY, FUEL FE
KE
000
[01]
09210-01580
PUMP ASSY, FUEL FE
KE
003
[01]
HOUSING SUB-ASSY,
003
[01]
HOUSING SUB-ASSY,
003-001
[1C]
ROD, FEED PUMP PUS
BLUE -8405
003-001
[1C]
ROD, FEED PUMP PUS
KEY -8405
003-001
[1C]
ROD, FEED PUMP PUS
YELLOW -8405
003-001
[1C]
ROD, FEED PUMP PUS
GREEN -8405
003-001
[1C]
ROD, FEED PUMP PUS
WHITE -8405
003-001
[1C]
ROD, FEED PUMP PUS
BROWN -8405
003-001
[01]
ROD, FEED PUMP PUS
8405-
003-001
[1C]
ROD, FEED PUMP PUS
BLUE -8405
003-001
[1C]
ROD, FEED PUMP PUS
KEY -8405
003-001
[1C]
ROD, FEED PUMP PUS
YELLOW -8405
003-001
[1C]
ROD, FEED PUMP PUS
GREEN -8405
003-001
[1C]
ROD, FEED PUMP PUS
WHITE -8405
003-001
[1C]
ROD, FEED PUMP PUS
BROWN -8405
003-001
[01]
ROD, FEED PUMP PUS
8405-
003-002
[01]
SEAL, OIL
D13,T8.2 -8405
003-002
[01]
SEAL, OIL
D14,T5.5 8405-
003-002
[01]
SEAL, OIL
D13,T8.2 -8405
003-002
[01]
SEAL, OIL
D14,T5.5 8405-
005
[02]
VALVE, FEED PUMP C
005
[02]
VALVE, FEED PUMP C
006
[02]
SPRING, FEED PUMP
006
[02]
SPRING, FEED PUMP
007
[02]
GASKET, CHECK VALV
ID16 COPPER
007
[02]
GASKET, CHECK VALV
ID16 COPPER
22513-77020 TOYOTA
008
[02]
PLUG, FEED PUMP CH
008
[02]
PLUG, FEED PUMP CH
011
[01]
PISTON, FEED PUMP
BLUE
011
[01]
PISTON, FEED PUMP
BLUE
013
[01]
ROLLER, FEED PUMP
013
[01]
ROLLER, FEED PUMP
014
[01]
PIN, FEED PUMP TAP
014
[01]
PIN, FEED PUMP TAP
015
[02]
BLOCK, FEED PUMP T
015
[02]
BLOCK, FEED PUMP T
016
[01]
RING, SNAP
ID28
016
[01]
RING, SNAP
ID28
017
[01]
SPRING, FEED PUMP
017
[01]
SPRING, FEED PUMP
018
[01]
WASHER, COPPER PLA
T1
018
[01]
WASHER, COPPER PLA
T1
019
[01]
PLUG, FEED PUMP PI
019
[01]
PLUG, FEED PUMP PI
020
[01]
SCREW, FUEL PIPE H
M14,L26
020
[01]
SCREW, FUEL PIPE H
M14,L26
021
[01]
FILTER, FEED PUMP
021
[01]
FILTER, FEED PUMP
022
[01]
SCREW, HOLLOW
M14,L26
022
[01]
SCREW, HOLLOW
M14,L10
90099-18010 TOYOTA
023
[04]
WASHER, FUEL PIPE
T1.2
023
[04]
WASHER, FUEL PIPE
T1.2
94712-77121 TOYOTA
024
[01]
TAPPET, FEED PUMP
024
[01]
TAPPET, FEED PUMP

Include in ##:

09210-01580 as PUMP ASSY, FUEL FE

Cross reference number



Part num
Firm num
Firm
Name
09210-01580 
 
PUMP ASSY, FUEL FE




Information:

Emergency Stopping
Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use Emergency shutoff devices or controls for normal stopping procedure.
Make sure that any external system components that have been operating to support engine operation are secured after any stop.Emergency Stop Buttons
Emergency Stop Button, shown mounted on a junction box.Emergency stops may be made by pushing the Emergency Stop Button located on the junction box (if equipped). Both the Button and the air inlet shutoff (if equipped) require resetting before the engine will start.
Control Panel Emergency Stop Button.If equipped with the EMCPII Control Panel, press the Emergency Stop Button for an emergency stop. The ECS must be reset before resuming operation. Move the ECS to the OFF/RESET position. The ECS can also be used to shut the engine off in an emergency. Move the ECS to the OFF/RESET position. The engine will immediately shut off.Manual Stopping
A manual shutoff shaft is provided to override the governor control. The shaft will move the fuel control linkage to the FUEL OFF position. Refer to the Model Views for the engine location of the shaft. The engine may be stopped by using the shaft and the Woodward Actuator (if equipped) or the Mechanical Governor (if equipped).
Typical Woodward Actuator Control Lever.If equipped with a Woodward Actuator, move the control lever to the FUEL OFF position.
Typical Mechanical Governor ControlIf equipped with a Mechanical Governor Control, move the control to the FUEL OFF position.Hold the lever at the FUEL OFF position until the engine stops.Air Shutoff (If Equipped)
Some engines are equipped with an air shutoff, located between the aftercooler and the turbocharger. If equipped with an air shutoff lever, move the lever to the OFF position.Manual Stop Procedure
There may be several ways to shut off your engine. Make sure the shutoff procedures are understood. Use the following general guidelines for stopping the engine.EPG Engines
If the ECS is in the AUTO position and the remote contact opens, the engine will run for a pre-programmed cool down period. This will only occur when the cool down mode is used. If the cool down mode is not used, the engine will shut off immediately.
If the ECS is in the AUTO position, the remote contact opens, and the cool down time expires, the CTR will be unlatched and the starting motors may be re-engaged.1. Open the main electrical circuit breaker to remove the load.2. The engine should be run for a cool down period before being shut off. This can be accomplished with the COOLDOWN STOP switch, or the operator can control the cool down and shut off.
To use the COOLDOWN/STOP switch, turn the ECS to the COOLDOWN/STOP position. The engine will operate for a pre-programmed time period. The timer will active the fuel shutoff after the cool down.Alternatively, after removing the load, allow the engine to run at rated speed for a cool down period of five minutes. Then turn the ECS to the OFF/RESET position, and the engine will immediately shut off.Industrial Engines
1. Disengage any driven equipment

Have questions with 09210-01580?





Group cross 09210-01580

Back to top