Rating:
Information pump assy, fuel fe Denso
KIT List:
Part name
Kit1
Kit2
Scheme #.#:
№
Qty
Part num
Name
Remarks
Manufacture num
Cross reference number
Part num
Firm num
Firm
Name
09210-00680
PUMP ASSY, FUEL FE
Information:
Table 1
Serial Numbers    
Version C    Version D    
N/A     1NW00001 & Up    
N/A     1PW00001 & Up    
N/A     1TW00001& Up    
2BM00001 to 2BM00122     2BM00123 & Up    
N/A     2FW00001 & Up    
N/A     2GW00001 & Up    
N/A     2HW00001 & Up    
N/A     3CW00001 & Up    
3DM00001 to 3DM00092     3DM00093 & Up    
N/A     3DW00001 & Up    
N/A     4AW00001 & Up    
4GM00001 to 4GM00211     4GM00212 & Up    
4TN00001 to 4TN00095     4TN00096 & Up    
6HN00001 to 6HN00155     6HN00156 & Up    
6PN00001 to 6PN00284     6PN00285 & Up    
6WN00001 to 6WN00134     6WN00135 & Up    
7HM00001 to 7HM00173     7HM00174 & Up    
7RN00001 to 7RN00462     7RN00463 & Up    
7SM00001 to 7SM00076     7SM00077 & Up    
8CN00001 to 8CN00143     8CN00144 & Up    
8EM00001 to 8EM00257     8EM00258 & Up    
8KN00001 to 8KN00142     8KN00143 & Up    
8RM00001 to 8RM00199     8RM00200 & Up    
9AN00001 to 9AN00120     9AN00121 & Up    
Version C of the ADEM II controller (ECM) has a primary data link for use with the CCM. This data link is called the CAT Data Link. The Module Identifier (MID) of this controller is a fixed value. Each controller on the CAT Data Link must have a unique MID. The CCM can only be connected to one Version C ECM on the CAT Data Link.
Version D of the ADEM II controller (ECM) also has a primary data link for use with the CCM. The value of the MID for the primary data link is fixed. Version D also has a secondary data link for use with the CCM. The Secondary CAT Data Link has a programmable MID. A maximum of eight different values is available for generator set applications. A maximum of three different values is available for marine applications.
EMCP II (basic model) has a primary data link for use with the CCM. This data link is called the CAT Data Link. The CAT Data Link has a programmable MID. A maximum of eight different values may be used for the MID.
EMCP II+ has the same primary data link as EMCP II (CAT Data Link) with a programmable value for the MID. The EMCP II+ also has a secondary data link for use with the CCM. The CCM Data Link has a programmable value for the MID. The CAT Data Link and the CCM Data Link have eight MID values.
The Secondary CAT Data Link and the CCM Data Link can be treated in the same manner on the 3500B Version D and the EMCP II+ applications.
There is a maximum of one CCM per data link.