09200-01650 PUMP ASSY, INJECTI Calibration Data


Rating:
3
Buy PUMP ASSY, INJECTI 09200-01650 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
Construction machine 6D125E
Engine
6D125E
Serial start-end
9506-
Info
Injector Nozzle
093500-6080
Injector nozzle: 0935006080

KIT List:

Part name
Kit1
Kit2
Pump assy, fuel fe
Body assy, injecti
Governor assy, mec

Components :

00.001
PUMP ASSY, INJECTI
NB6,RSV -0010
00.001
PUMP ASSY, INJECTI
NB6,RSV 0010-
01.002
PUMP ASSY, FUEL FE
KE
01.003
COUPLING ASSY
SD
01.004
BODY ASSY, INJECTI
NB6
02.005
COVER, BEARING
DUMMY
01.006
GOVERNOR ASSY, MEC
RSV

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09200-01650
PUMP ASSY, INJECTI
NB6,RSV -0010
000
[01]
PUMP ASSY, INJECTI
NB6,RSV 0010-
003
[01]
BODY ASSY, INJECTI
NB6
004
[01]
GOVERNOR ASSY, MEC
RSV
005
[02]
BOLT, W/WASHER
M8,L14
006
[01]
COVER, CONTROL RAC
007
[01]
NUT, TIMER ROUND
008
[01]
WASHER, COUNTERSUN
T1.5ID18
009
[01]
KEY, WOODRUFF
W5,H7.5
010
[01]
PUMP ASSY, FUEL FE
KE
011
[01]
COVER, PRIMING PUM
012
[01]
WASHER, COPPER PLA
T1.5
014
[01]
COUPLING ASSY
SD
016
[01]
BOLT, W/WASHER
M8,L20
017
[04]
BOLT, W/WASHER
M8,L16
020
[01]
BOLT, W/WASHER
M8,L22

Include in ##:

09200-01650 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
09200-01650 
 
PUMP ASSY, INJECTI

Test Calibration Data:

0920001650 61507-21220




Information:

Delco-Remy Starting Motor
Fig. 1-Delco-Remy Starting MotorRemoval
Starter is located on either right or left side of engine at the rear.Disconnect battery negative (-) cable.Disconnect wires from starting motor.Remove cap screws that attach motor to flywheel housing. The JDE-80 starter wrench may be necessary to remove the rear attaching cap screw.Testing And Diagnosis
Solenoid Tests (Starting Motor Removed)
Fig. 2-Solenoid Pull-In Test Testing Pull-In WindingsDisconnect field connector from solenoid motor terminal. Connect ammeter in series with a carbon pile resistor to terminal "S" and to battery. Connect voltmeter (1) to terminal "S" and to solenoid motor terminal (Fig. 2). With carbon pile (2) in the off position, connect other battery post (3) to solenoid motor terminal. Quickly adjust the carbon pile (2) to obtain 5 volts. The ammeter (4) reading should be 13 to 15.5 amps. Testing Hold-In WindingsDisconnect solenoid. Connect ammeter in series with a switch to terminal "S" and to battery. Connect voltmeter to terminal "S" and to solenoid ground. Connect carbon pile resistor across the battery. Connect other battery post to solenoid ground. Close the switch and adjust carbon pile to obtain 10 volts. The ammeter reading should be 14.5 to 16.5 amps. High Ammeter ReadingWindings are grounded or short circuited Low Ammeter ReadingExcessive resistance is present (usually in a connection) No Ammeter ReadingWindings are open circuitedTo prevent overheating, do not energize the pull-in winding longer than 15 seconds. Current draw will decrease as the winding temperature increases.If the fault cannot be repaired and the solenoid performance is questionable, replace the windings.No Load Starting Motor Test (Fig. 3)
Fig. 3-No Load Starter Test CircuitPlace starter in a vise.Connect the circuit in Fig. 3 starting with the battery positive terminal (2) with heavy wire to the ammeter (3) then to the "BAT." contact of the solenoid. Connect a switch across the "BAT." and S of the solenoid.Place a voltmeter from the M terminal to the starter motor casing. Connect the starter motor casing to the negative of the battery. Connect a carbon pile to the positive and negative of the battery to adjust the voltage. Connect a tachometer to the starter motor.
Fig. 4-Test Data For A Delco-Remy StarterThe meters should read as follows (Fig. 4).Interpret the test results as follows:1. Rated current draw and no load speed indicates normal condition of the starting motor.2. Low free speed and high current draw indicates: a. Too much friction - tight, dirty, or worn bearings, bent armature shaft or loose pole shoes, allowing armature to drag.b. Shorted armature. This can be further checked on a growler after disassembly.c. Grounded armature or fields. Check further after disassembly.3. Failure to operate with high current draw indicates: a. A direct ground in the terminal or fields.b. Frozen bearings (this should have been determined by turning the armature by hand).4. Failure to operate with no current draw indicates: a. Open field circuit. This can be checked after disassembly by inspecting internal conditions and tracing circuit with a test lamp.b. Open armature coils. Inspect the commutator for badly burned

Have questions with 09200-01650?





Group cross 09200-01650