09000-08461 PUMP ASSY, INJECTI Denso Cross


Rating:
29
Buy PUMP ASSY, INJECTI 09000-08461 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Components :

00.001
PUMP ASSY, INJECTI
A6,RSV
01.002
BODY ASSY, INJECTI
A6:COLD SPEC OLD
02.003
COVER, BEARING
DUMMY
01.004
GOVERNOR ASSY, MEC
RSV
01.005
TIMER ASSY, AUTOMA
SA/2SP
01.006
PUMP ASSY, FUEL FE
KE
01.007
COUPLING ASSY

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09000-08461
PUMP ASSY, INJECTI
A6,RSV
22010-2550 HINO
007
[01]
BODY ASSY, INJECTI
6 305 1200 80 HINO
008
[01]
GOVERNOR ASSY, MEC
RSV
22310-1710 HINO
009
[06]
BOLT, W/WASHER
M6,L14
6 306 1001 00 HINO
011
[01]
BOLT, W/WASHER
M8,L18
22815-2820A HINO
013
[01]
COVER, CONTROL RAC
M18L23.0
22114-1130A HINO
014
[01]
TIMER ASSY, AUTOMA
SA/2SP
22510-1350 HINO
015
[01]
NUT, TIMER ROUND
22353-1050A HINO
016
[01]
KEY, WOODRUFF
T3.0
22891-1040A HINO
017
[01]
WASHER, SPRING
ID12.2
22873-1310A HINO
018
[01]
PUMP ASSY, FUEL FE
22570-1170 HINO
019
[01]
COVER, PRIMING PUM
6 053 1552 60 HINO
022
[01]
COUPLING ASSY
22610-1090A HINO
023
[01]
COUPLING, INJECTIO
22612-1100A HINO

Include in ##:

09000-08461 as PUMP ASSY, INJECTI

Cross reference number



Part num
Firm num
Firm
Name
09000-08461 
22010-2550 
PUMP ASSY, INJECTI




Information:

If the engine has been operating at high load, run at low idle for at least three minutes before stopping. This cool down will reduce and stabilize internal engine coolant and oil temperatures before stopping the engine.If the engine has been operating at low loads, run the engine at low idle for 30 seconds before stopping.Make sure the shutoff procedure is understood. Refer to the Stopping the Engine instructions in the Generator Set Control Panel topic in this publication. Use the following general guidelines for stopping the engine.1. Open the Main electrical circuit breaker/Remove load from engine.2. Move the governor control to no more than half engine speed. Run the engine for three to five minutes.3. Reduce the engine speed to low idle.4. The engine may be stopped by using the Woodward Governor (if equipped), the Mechanical Governor (if equipped), or the solenoid shutoff switch.Woodward Actuator (If Equipped)
If equipped with a Woodward Actuator, move the control lever upward or forward, depending on the installation. Hold the lever to the OFF or STOP position until the engine stops.Mechanical Governor Control
A manual shutoff lever is provided to shut off the fuel from the fuel injection pump and override the governor control. The manual shutoff lever is located on the side of the pump.The engine can be shut OFF by rotating and holding the manual shutoff lever in the clockwise (CW) direction. If equipped with a Mechanical Governor Control, to move control to the SHUT OFF position: pull upward on the vernier hand grip while pushing down on thumb button. This shutdown will only move the fuel control linkage (rack) to the FUEL-OFF position. This does not shut off the air inlet.Solenoid Shutoff
Move the Control Panel Engine Control Switch (ECS, if equipped) to the STOP position.After Stopping the Engine
1. Fill the fuel tank to prevent accumulation of moisture in the fuel.2. Check the coolant level. Maintain the cooling system to 13 mm (1/2 inch) from bottom of the fill pipe. If freezing temperatures are expected, allow the radiator and engine jacket water system to cool, then check the coolant for proper antifreeze protection. The cooling system must be protected against freezing to the lowest expected ambient (outside) temperature. Add the proper coolant and water mixture if necessary.3. Check the crankcase oil level. Maintain the oil level between the ADD and FULL marks in the FULL RANGE zone on the dipstick.4. Repair any leaks, perform minor adjustments, tighten loose bolts, etc. 5. Note the service hour meter reading. Perform periodic maintenance as instructed in the Maintenance Schedule.

Have questions with 09000-08461?





Group cross 09000-08461

Back to top