09000-05300 PUMP ASSY, INJECTI Calibration Data


Rating:
10
Buy PUMP ASSY, INJECTI 09000-05300 genuine, new aftermarket engine parts with delivery

Information pump assy, injecti Denso

Product
Fuel Injection Pump
Vehicle engine
INDUSTRIAL 4DQ50C
Engine
4DQ50C
Serial start-end
7503--8201
Info
Injector Nozzle
093500-0180
Injector nozzle: 0935000180

KIT List:

Part name
Kit1
Kit2
Body assy, injecti
Pump assy, fuel fe

Components :

00.001
PUMP ASSY, INJECTI
A4,RUV
01.002
BODY ASSY, INJECTI
A4:DRIV.16.8
01.003
PUMP ASSY, FUEL FE
KS

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
PUMP ASSY, INJECTI
A4,RUV
005
[01]
BODY ASSY, INJECTI
A4:DRIV.16.8
006
[01]
GOVERNOR ASSY, MEC
007
[01]
PUMP ASSY, FUEL FE
KS
008
[06]
BOLT, W/WASHER
M6,L14
009
[01]
COVER, CONTROL RAC
010
[01]
NUT, HEXAGON
M12
011
[01]
WASHER, SPRING
T2.5
012
[01]
KEY, WOODRUFF
014
[01]
WASHER, PLATE
M6,T1.5
015
[01]
COVER, PRIMING PUM
-8505

Cross reference number



Part num
Firm num
Firm
Name
09000-05300 
 
PUMP ASSY, INJECTI

Test Calibration Data:

0900005300 30661-57060




Information:

Required Equipment
The following is a list of equipment required to test and calibrate temperature contactors.* 6V-7070 Multimeter or Equivalent A multimeter is used to verify the actuation and deactuation settings. This is done by checking for continuity between two terminals inside the contactor.* Heat Bath A heat bath is used to maintain a constant elevated temperature with the temperature probe submersed into a silicone heating fluid. This allows for the calibration of the actuation and deactuation settings. It must be temperature controlled and meet the following specifications:a. Capable of obtaining a temperature of 150° C (302° F) or have at least a 20° C (40° F) higher temperature capacity than the specified set point.b. Maintain the temperature within 1° C ( 2° F) maximum temperature difference.c. Must be equipped with a thermometer or digital display temperature read-out accurate to within 0.5° C ( 1° F).d. Circulate the heating fluid to maintain a uniform temperature.e. Must have a minimum bath capacity of 0.5 L (31.25 cu in). Also requires a working depth large enough to fully immerse the temperature probe.f. Must be compatible with silicone fluids.g. Can be a portable self-contained unit. The heat baths listed in Chart B meet the specified requirements and can be purchased from:Cole-Parmer Instruments Co.
7425 North Oakpark Ave.
Niles, IL, 60714 U.S.A.
Phone (800) 323-4340
Fax: (708) 647-9660
* Heat Bath Fluid The heat bath fluid must be able to obtain and maintain the required contactor actuation and deactuation temperatures. For the temperatures required for the calibration procedure, silicone fluid must be used. Silicone fluid has a temperature range between 10° C (50° F) and 230° C (446° F). Silicone fluid can be purchased from Cole-Parmer by ordering G-01294-40. The fluid comes in a 3.8 Liter (1 gal) container.
Use extreme caution around heat baths with high temperature fluids. High temperature fluids can cause severe burns.
Calibration Procedure
Use the following procedure to test and calibrate the temperature contactors.1. If connected, disconnect the contactor from the power supply. Mark the terminal location and disconnect the three wires from terminals 1, 2, and 4.
High voltage electrical shock is possible. The contactor must be disconnected from the power supply and the wires disconnected from terminals 1, 2, and 4. Failure to follow this recommendation can result in serious bodily injury.
2. Locate and record the part number of the temperature contactor in Chart A. This will determine the actuation and deactuation temperatures. If the temperature contactor is used in extreme ambient temperatures there will be a scale deviation from the required actuation and deactuation temperatures. Refer to the "Calculating Scale Correction for Severe Temperature Applications" section in this Special Instruction.
Temperature Contactor
(1) Housing cover. (2) Housing cover screws. (3) Temperature probe. (4) Capillary tube.3. Loosen housing cover screws (2) and remove housing cover (1).4. Fill the heat bath unit with silicone fluid and heat it to approximately 5° C (10° F) below the actuation temperature setting. Do not immerse the temperature probe at this time.
Nomenclature Of Internal Parts
(5). Lock screw. (6) Range spindle.

Have questions with 09000-05300?





Group cross 09000-05300