Rating:
Information holder & nozzle se Denso
Product
Nozzle & Nozzle Holder
Vehicle engine
DYNA 15B-FTE
Engine
15B-FTE
Serial start-end
0105-
Info
Injector Nozzle
TOYOTA
HOLDER & NOZZLE SE
AA
- ILL NO.10 THE NOZZLE KIT P/N 093410-0030 IS SUPPLIED
- AS SPARE PARTS ONLY.
Components :
Scheme #.#:
№
Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09350-07530
HOLDER & NOZZLE SE
Include in ##:
09350-07530
as HOLDER & NOZZLE SE
Nozzle Specification:
Parts number
0935007530 TOYOTA
Nozzle
0934007870
First opm
17.65-18.63
First op
180.0-190.0
Second om
29.52-30.50
Second op
301-311
Torquen
24.5-34.3
Torque
2.5-3.5
Prelift
0.04MIN.
Max lift
0.33-0.38
Engine
DYNA 15B-FTE
Information
Cross reference number
Part num
Firm num
Firm
Name
09350-07530
TOYOTA
HOLDER & NOZZLE SE
Information:
Flow of coolantWater Pump
Removal and Inspection
Removal sequence and points to check on water pump(1) Cooling fan(2) Fan spacer(3) Water pump pulley(4) Fan belt(5) Water bypass hose(6) Water pump assembly Key Points for RemovalRemoval of the water pump pulley and fa belt is possible after loosening slightly both the adjusting bolt (1) and support bolt (2). This allows the alternator to be moved and then the V-belt slackened.
Removing water pump pulley Key Points for InspectionTurn the pump by hand to check the impeller shaft for smooth and quiet rotation. If irregular or noisy rotation is detected, replace them as an assembly.
Inspecting impeller and shaft rotationInstallation
Perform installation by following the removal sequence in reverse: Key Points for Inspection(1) Install the six water pump mounting bolts in their correct locations by referring to the figure on the right for the nominal diameters and lengths from bottom of head.
Correct locations of water pump mounting bolts(2) Use a new gasket when installing the water pump.(3) Adjust the fan belt tension according to the following specification.Unit: mm (in.)
Fan belt tension adjustmentThermostat
Disassembly
Removal sequence and points to check on the thermostat(1) Water hose(2) Water outlet fitting(3) Thermostat(4) Thermostat fitting(5) Thermo switchInspection
Key Points for Removal(1) Operation Test of Thermostat
Put the thermostat in a container of water. Heat the water and record both of the temperatures at which the valve starts to open and at which the valve lift reaches 8 mm (0.3 in.). If the readings do not conform to the specification below, replace the thermostat.
Operation test of thermostat
Carry out this operation with extreme care to avoid burns and prevent fire.
Installation
Except that the instructions shown below are to be followed, perform installation by following the removal sequence in reverse: Key Points for Inspection(1) Thermo Switch
Apply sealant to the threads an tighten to the specified torque.
Installing thermo switch(1) Thermostat
Make sure that the thermostat flange fits correctly into the counterbore in the thermostat fitting.
Installing thermostat