09350-07340 HOLDER & NOZZLE SE Denso Cross


Rating:
8
Buy HOLDER & NOZZLE SE 09350-07340 genuine, new aftermarket engine parts with delivery

Information holder & nozzle se Denso

Product
Nozzle & Nozzle Holder
Vehicle engine
E SERIES 2R
Engine
2R
Serial start-end
9906-
Info
Injector Nozzle

Components :

00.001
HOLDER & NOZZLE SE

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09350-07340
HOLDER & NOZZLE SE
001
[01]
HOLDER ASSY, NOZZL
001-001
[01]
BODY SUB-ASSY, NOZ
001-002
[01]
PIN, NOZZLE HOLDER
001-003
[01]
SPRING, NOZZLE HOL
001-004
[01]
NUT, NOZZLE RETAIN
BLACK -0603
001-004
[01]
NUT, NOZZLE RETAIN
WHITE 0604-
001-005
[01]
DISTANCE PIECE
001-006
[1C]
WASHER
T0.900
001-006
[1C]
WASHER
T0.925
001-006
[1C]
WASHER
T0.950
001-006
[1C]
WASHER
T0.975
001-006
[1C]
WASHER
T1.000
001-006
[1C]
WASHER
T1.025
001-006
[1C]
WASHER
T1.050
001-006
[1C]
WASHER
T1.075
001-006
[1C]
WASHER
T1.100
001-006
[1C]
WASHER
T1.125
001-006
[1C]
WASHER
T1.150
001-006
[1C]
WASHER
T1.175
001-006
[1C]
WASHER
T1.200
001-006
[1C]
WASHER
T1.225
001-006
[1C]
WASHER
T1.250
001-006
[1C]
WASHER
T1.275
001-006
[1C]
WASHER
T1.300
001-006
[1C]
WASHER
T1.325
001-006
[1C]
WASHER
T1.350
001-006
[1C]
WASHER
T1.375
001-006
[1C]
WASHER
T1.400
001-006
[1C]
WASHER
T1.425
001-006
[1C]
WASHER
T1.450
001-006
[1C]
WASHER
T1.475
001-006
[1C]
WASHER
T1.500
001-006
[1C]
WASHER
T1.525
001-006
[1C]
WASHER
T1.550
001-006
[1C]
WASHER
T1.575
001-006
[1C]
WASHER
T1.600
001-006
[1C]
WASHER
T1.625
001-006
[1C]
WASHER
T1.650
001-006
[1C]
WASHER
T1.675
001-006
[1C]
WASHER
T1.700
001-006
[1C]
WASHER
T1.725
001-006
[1C]
WASHER
T1.750
001-006
[1C]
WASHER
T1.775
001-006
[1C]
WASHER
T1.800
001-006
[1C]
WASHER
T1.825
001-006
[1C]
WASHER
T1.850
001-006
[1C]
WASHER
T1.875
001-006
[1C]
WASHER
T1.900
001-006
[1C]
WASHER
T1.925
001-006
[1C]
WASHER
T1.950
001-008
[01]
NUT, HEXAGON
M12
002
[01]
NOZZLE ASSY

Include in ##:

09350-07340 as HOLDER & NOZZLE SE

Nozzle Specification:

Parts number
0935007340 MAZDA
Nozzle
0934006050
First opm
14.79-15.58
First op
151-159
Second om
-
Second op
-
Torquen
44.1-49.0
Torque
4.5-5.0
Prelift
-
Max lift
0.95
Engine
E SERIES 2R
Information

Include as Nozzle:

0965003060 as Nozzle

Cross reference number



Part num
Firm num
Firm
Name
09350-07340 
 
HOLDER & NOZZLE SE




Information:

Fuel System
Testing 9L9263 Fuel Injection Nozzles
8S2242 Nozzle Testing Group.8S2245 Injector Cleaning Tool Group.9S7354 Torque Wrench.9S3093 Adapter.Before testing a fuel injection pump or nozzle from an engine that is misfiring or puffing black smoke, a simple check can be made to determine which cylinder is causing the difficulty.With the engine running at a speed that makes the misfiring most pronounced, momentarily loosen the fuel line nut on an injection pump sufficiently to "cut out" that cylinder. Check each cylinder in the same manner. If one is found where loosening makes no difference in the irregular operation or causes puffing of black smoke to cease, the pump and valve for only that cylinder need be tested.Exhaust port temperature, when the engine is running at low idle speed, can be an indication of injection nozzle condition. Low temperature at an exhaust manifold port, indicates no fuel to the cylinder and a possibility of a clogged nozzle. Exceptionally high exhaust port temperature may indicate excess fuel injection caused by poor fuel cut off. Do not attempt to test or disassemble nozzles without the proper service tools.Before testing, remove loose carbon from the tip with the 8S2258 Brass Wire Brush. Remove the carbon seal dam and clean the groove and the body below the groove in the same manner. Any staining in this area is normal and not detrimental to the nozzle body. Carbon accumulations should be removed, but excessive brushing will remove the coating on the nozzle. Perform all test before cleaning or adjusting a nozzle. A test may show that the nozzle can not be used again.
When testing, keep the nozzle tip directed away from the operator and into the 8S2270 Fuel Collector to contain the spray. Fuel from the spray orifices can penetrate clothing and skin causing serious infection.
Connect nozzle (4) to tester (1) using tube assembly (2) and adapter (3). The nozzle may be tightened by hand if the 1H1023 Seal is not damaged.
Always use clean Kent-Moore J23300-585 or Shell 66631 calibration oil or equivalent when testing. Dirty test oil will damage nozzle components.
Kent-Moore J2300-585 calibration oil may be purchased from Kent-Moore Corp. 1501 South Jackson St., Jackson, Michigan 49203. Shell 66631 calibration oil may be purchased from Shell Oil Company.
CONNECTING NOZZLE TO TESTER
1. 8S2267 Nozzle Tester. 2. 8S2268 Tube Assembly. 3. 9S3093 Adapter. 4. Nozzle.Opening Pressure Test
1. Close the gauge protector valve and the on-off valve. Open the pump isolator valve. Flush the nozzle by operating the tester for 10 to 15 strokes at a rate of 60 strokes per minute.2. Open the gauge protector valve. Raise the pressure slowly until the nozzle valve opens. The gauge reading may drop sharply if the valve chatters, or may stay nearly constant when the valve opens. Opening pressures should be as listed in the chart. If opening pressure is less than 2200 psi (154.7 kg/cm2), do not use the nozzle again. Lack of chatter or atomized spray during Step 2 does not indicate a faulty valve. Used nozzles that have

Have questions with 09350-07340?





Group cross 09350-07340

Back to top