Rating:
Information holder & nozzle se Denso
Product
Nozzle & Nozzle Holder
Vehicle engine
BUS F17E
Engine
F17E
Serial start-end
8912-
Info
Injector Nozzle
Components :
Scheme #.#:
№
Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09350-04610
HOLDER & NOZZLE SE
-0605
000
[01]
09350-04610
HOLDER & NOZZLE SE
0605-
Include in ##:
09350-04610
as HOLDER & NOZZLE SE
09350-04610 HOLDER & NOZZLE SE
Nozzle Specification:
Parts number
0935004610 HINO
Nozzle
0934002410
First opm
15.19-15.97
First op
155-163
Second om
26.95-27.73
Second op
275-283
Torquen
58.8-78.4
Torque
6.0-8.0
Prelift
0.107-0.143
Max lift
Engine
BUS F17E
Information
Include as Nozzle:
Cross reference number
Part num
Firm num
Firm
Name
09350-04610
HOLDER & NOZZLE SE
Information:
System Operation
A thermocouple is a temperature sensor. The thermocouple consists of two different metals. The metals are joined together at one end. A small voltage is produced when the junction is heated. The change in voltage is interpreted by an electronic device in order to determine a change in temperature. The MMS uses K type thermocouples. The K type thermocouples have ranges from -200 °C (-328 °F)to 1260 °C (2300 °F). This temperature range corresponds to a voltage range of negative 5.9 mV to 51.0 mV.The signal is used in order to trigger alarms and the signal is used in order to display the parameter.
Illustration 1 g00563634
Diagram of the thermocouple
Illustration 2 g00563637
Schematic of the thermocoupleFunctional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Stop.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
A thermocouple is a temperature sensor. The thermocouple consists of two different metals. The metals are joined together at one end. A small voltage is produced when the junction is heated. The change in voltage is interpreted by an electronic device in order to determine a change in temperature. The MMS uses K type thermocouples. The K type thermocouples have ranges from -200 °C (-328 °F)to 1260 °C (2300 °F). This temperature range corresponds to a voltage range of negative 5.9 mV to 51.0 mV.The signal is used in order to trigger alarms and the signal is used in order to display the parameter.
Illustration 1 g00563634
Diagram of the thermocouple
Illustration 2 g00563637
Schematic of the thermocoupleFunctional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Stop.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.