09350-04560 HOLDER & NOZZLE SE Denso Cross


Rating:
8
Buy HOLDER & NOZZLE SE 09350-04560 genuine, new aftermarket engine parts with delivery

Information holder & nozzle se Denso

Product
Nozzle & Nozzle Holder
Vehicle engine
INDUSTRIAL 4DR
Engine
4DR
Serial start-end
8912-
Info
Injector Nozzle

Components :

00.001
HOLDER & NOZZLE SE

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09350-04560
HOLDER & NOZZLE SE
001
[01]
HOLDER ASSY, NOZZL
001-001
[01]
BODY SUB-ASSY, NOZ
001-002
[01]
PIN, NOZZLE HOLDER
001-003
[01]
SPRING, NOZZLE HOL
001-004
[01]
NUT, NOZZLE RETAIN
001-005
[01]
DISTANCE PIECE
001-006
[1C]
WASHER
T1.0
001-006
[1C]
WASHER
T1.05
001-006
[1C]
WASHER
T1.1
001-006
[1C]
WASHER
T1.15
001-006
[1C]
WASHER
T1.2
001-006
[1C]
WASHER
T1.25
001-006
[1C]
WASHER
T1.3
001-006
[1C]
WASHER
T1.35
001-006
[1C]
WASHER
T1.4
001-006
[1C]
WASHER
T1.45
001-006
[1C]
WASHER
T1.5
001-006
[1C]
WASHER
T1.55
001-006
[1C]
WASHER
T1.6
001-006
[1C]
WASHER
T1.65
001-006
[1C]
WASHER
T1.7
001-006
[1C]
WASHER
T1.75
001-006
[1C]
WASHER
T1.8
001-006
[1C]
WASHER
T1.85
001-006
[1C]
WASHER
T1.9
001-006
[1C]
WASHER
T1.95
001-007
[01]
WASHER
001-009
[01]
NUT, HEXAGON
M12
002
[01]
NOZZLE ASSY

Include in ##:

09350-04560 as HOLDER & NOZZLE SE

Nozzle Specification:

Parts number
0935004560 MITSUBISHI
Nozzle
0934001400
First opm
11.76-12.74
First op
120-130
Second om
-
Second op
-
Torquen
58.8-78.4
Torque
6.0-8.0
Prelift
-
Max lift
Engine
INDUSTRIAL 4DR
Information

Include as Nozzle:

0930003380 as Nozzle

Cross reference number



Part num
Firm num
Firm
Name
09350-04560 
 
HOLDER & NOZZLE SE




Information:


Illustration 1 g00565418
4W-8471 Time Delay Relay
Use a 6V-7070 Digital Multimeter, a stopwatch, and a battery (8 volts to 40 volts) for this test.
Connect the positive lead of the voltage source to terminal (TD-4) of the time delay relay. Connect the negative lead to terminal (TD-3). If the test is done on an engine, the start/stop switch must be in the STOP position in order to power terminal (TD-6). All connections must be maintained until the tests are completed.
Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 1
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Connect the positive lead of the voltage source to terminal (TD-1). If the time delay relay is tested on the engine do not leave the voltage source hooked to terminal (TD-1) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 2
Terminals     Relay Position    
5-6     Open    
6-7     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 3
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    Note: If a jumper is normally installed across terminals (TD-2) and (TD-3), the jumper must be removed before performing Step 5.
Connect the positive lead of the voltage source to terminal (TD-2). If the time delay relay is tested on the engine, do not leave the voltage source on terminal (TD-2) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 4
Terminals     Delay Time of Relay Position    
0 to 8 seconds 10 seconds or more    
5-6     Closed     Open    
6-7     Open     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 5
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    
Remove the voltage source from terminal (TD-4). Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 6
Terminals     Relay Position    
5-6     Closed    
6-7     Open    

Have questions with 09350-04560?





Group cross 09350-04560

Back to top