09627-01490 GOVERNOR ASSY, TOR Denso Cross


Rating:
20
Buy GOVERNOR ASSY, TOR 09627-01490 genuine, new aftermarket engine parts with delivery

Information governor assy, tor Denso

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09627-01490
GOVERNOR ASSY, TOR
001
[01]
LEVER, GUIDE
002
[01]
LEVER SUB-ASSY, TE
003
[01]
LEVER SUB-ASSY, TO
004
[01]
PIN, LEVER SUPPORT
D5,L43
005
[1C]
WASHER, GOVERNOR T
T2.0,ID5
005
[1C]
WASHER, GOVERNOR T
T2.2,ID5
005
[1C]
WASHER, GOVERNOR T
T2.4,ID5
006
[2C]
WASHER, GOVERNOR T
T1.0,OD7
006
[2C]
WASHER, GOVERNOR T
T1.2,OD7
007
[1C]
WASHER, GOVERNOR T
T2.0OD10
007
[1C]
WASHER, GOVERNOR T
T2.2OD10
007
[1C]
WASHER, GOVERNOR T
T2.4OD10
008
[1C]
SPRING, DAMPER
L7.6
008
[1C]
SPRING, DAMPER
L8.0
008
[1C]
SPRING, DAMPER
L8.4
008
[1C]
SPRING, DAMPER
L8.8
008
[1C]
SPRING, DAMPER
L8.6
008
[1C]
SPRING, DAMPER
L9.0
008
[1C]
SPRING, DAMPER
L9.2
008
[1C]
SPRING, DAMPER
L9.4
008
[1C]
SPRING, DAMPER
L9.6
008
[1C]
SPRING, DAMPER
L9.8
008
[1C]
SPRING, DAMPER
L10.0
008
[1C]
SPRING, DAMPER
L10.2
008
[1C]
SPRING, DAMPER
L8.1
008
[1C]
SPRING, DAMPER
L8.2
008
[1C]
SPRING, DAMPER
L8.3
008
[1C]
SPRING, DAMPER
L8.5
008
[1C]
SPRING, DAMPER
L8.7
008
[1C]
SPRING, DAMPER
L8.9

Include in ##:

09627-01490 as GOVERNOR ASSY, TOR

Cross reference number



Part num
Firm num
Firm
Name
09627-01490 
 
GOVERNOR ASSY, TOR




Information:

Measuring Cleanliness
Fluid cleanliness can be measured by taking fluid samples from various machine compartments. Your Cat dealer can analyze the samples. Particle contaminants are typically measured by particle counters. Chemical contaminants can be measured by specific analysis techniques such as oxidation, water, or soot tests. Some chemical contaminants, such as water in fuel, can interfere with the particle counters and can be counted as particles. Refer to your Cat S O S lab or to your Cat dealer for more information.The number of particles in fluids is expressed in "ISO (International Organization for Standardization)" ratings. "ISO 4406" Standard classifies fluid cleanliness by the number and size of particles in 1 milliliter of fluid. "ISO 4406" Standard measures particle size in µm (microns) and reports the resulting count in three code ranges X, Y & Z. The three code range defines the size and distribution of particles in 1 milliliter of fluid:
The first code range, X represents the number of particles equal to or larger than 4 µm per milliliter of fluid.
The second code range, Y represents the number of particles equal to or larger than 6 µm per milliliter of fluid.
The third code range, Z represents the number of particles equal to or larger than 14 µm per milliliter of fluid.An example of an "ISO 4406" particle count is 18/16/13. Cat "ISO" cleanliness recommendations are expressed as two or three codes, depending on the machine system. The three code range follows "ISO 4406" definitions and is used for liquid fuels such as diesel and gasoline. The two code system, example "ISO -/16/13", is used for certain lubricant systems. In the two code system, the first number is the number of particles equal to or larger than 4 µm per milliliter of fluid. This number is not required and may be represented by a dash (-). The second number (Y) and the third number (Z) follow "ISO 4406" definitions. Cat reports the Y and Z codes for lubricating oils to keep consistency with older data and reports.An example of the particle size and distribution of the "ISO 4406" codes is given in Table 1.
Table 1
ISO 4406 Code Number of particles in 1 milliliter of fluid
4µm and up 6µm and up 14µm and up
"ISO 18/16/13" 1300 - 2500 320 - 640 40 - 80
"ISO 21/19/17" 10000 - 20000 2500 - 5000 80 - 160 Note: Several factors affect the results of particle counts. The factors include the cleanliness of the equipment used to obtain the sample, sample techniques, the cleanliness, and type of sample container, particle counter accuracy (calibration, maintenance, and process), and the environment where the sample is procured. Samples should be taken at representative locations in the fluid circulation system or the fluid distribution system when possible. The sample should be protected adequately from contamination during transport to the lab for analysis.In addition, particle counters may count water droplets and air bubbles as particulate contamination.Note: American Society for Testing and Measurement has developed "ASTM D7619" “Standard Test Method