Rating:
Information element sub-assy, Denso
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$28.99
05 Jun 2024
CN: Diesel Injection Par
1PC Plunger and Barrel Assembly 090150-5683 5683 Automotive Pump Element Fits for Komatsu SAA6D108E SAA6D108 SA6D108
Generic ➽Manufacturer Part Number:090150-5683, Stamping No.: 5683. || ➽Package: 1 piece of plungers and barrels.Neutral packing. || ➽Premium Quality:Our plungers and barrels made of premium strength metal and composite plastic.we have a good air and fuel mixing ability and excellent ability of fuel pump systems,and plunger assembly be inspected reliability and durability in the factory. || ➽Notice:Please you carefully check your vehicle plunger barrel and make sure that the Part number must be completely the same as our description fitment,if you have any problem,please you contact us by email,we will have professional customer service within 24 hours. || ➽Upgrade your engine with the 090150-5683 Fuel Plungers and Barrels. These high-quality diesel parts are designed to optimize fuel delivery, resulting in improved engine performance, increased power, and enhanced fuel efficiency.Experience smooth and reliable operation with the Fuel Plungers and Barrels.
Generic ➽Manufacturer Part Number:090150-5683, Stamping No.: 5683. || ➽Package: 1 piece of plungers and barrels.Neutral packing. || ➽Premium Quality:Our plungers and barrels made of premium strength metal and composite plastic.we have a good air and fuel mixing ability and excellent ability of fuel pump systems,and plunger assembly be inspected reliability and durability in the factory. || ➽Notice:Please you carefully check your vehicle plunger barrel and make sure that the Part number must be completely the same as our description fitment,if you have any problem,please you contact us by email,we will have professional customer service within 24 hours. || ➽Upgrade your engine with the 090150-5683 Fuel Plungers and Barrels. These high-quality diesel parts are designed to optimize fuel delivery, resulting in improved engine performance, increased power, and enhanced fuel efficiency.Experience smooth and reliable operation with the Fuel Plungers and Barrels.
Include in ##:
Cross reference number
Part num
Firm num
Firm
Name
09015-05683
ELEMENT SUB-ASSY,
Information:
Always determine the cause of the engine shutdown. Make necessary repairs before attempting restarting the engine.
Air Shutoff Solenoid (If Equipped)
This optional solenoid is located on top of the engine in the air inlet system. When the solenoid is activated, the solenoid mechanically shuts off inlet air to the engine. The solenoid can only be activated by the overspeed switch or the emergency stop switch. The air shutoff must be reset before the engine can be restarted.Fuel Shutoff Solenoid
This solenoid is located on the governor or on the fuel injection pump. When the solenoid is activated, the solenoid moves the fuel rack (either directly or through the governor) to the FUEL OFF position.Overspeed Shutoffs
Magnetic pickup, (1), mounted in the flywheel housing (2).A magnetic pickup mounted in the flywheel housing senses the passage of the flywheel ring gear teeth. Should the engine speed increase above the overspeed setting of the Electronic Overspeed Switch (118 percent of rated engine speed), the magnetic pickup will sense the overspeed and send a signal to the Electronic Overspeed Switch. The Electronic Overspeed Switch activates both the air (if equipped) and fuel shutoff solenoids.The shutoffs must be reset before the engine will restart. A reset button on the Electronic Overspeed Switch (in the junction box) must be pushed to open the overspeed switch. The air shutoff lever (at the top of the air inlet housing) must be manually reset.Oil Pressure Switches
Typical example of oil pressure switches, mounted in the rear of the junction box.An oil pressure switch has wires connected to the electrical system for alarm or shutoff functions. The oil pressure switch senses oil pressure at the bearing oil gallery. If sufficient oil pressure is not achieved after engine starting, or if the engine has been running normally and then loses oil pressure, the fuel shutoff solenoid is energized to shut the engine off. No resetting procedure is required.Engine Step Oil Pressure
This is an adjustable engine speed setting that protects the engine from a failure caused by too little oil pressure for a specified speed range. This option requires two different oil pressure switches. One switch has a high pressure rating- when the engine is running above the speed setting, the engine must maintain oil pressure higher than the switch rating. The other switch has a low pressure rating- an engine running below the speed setting must maintain oil pressure above the low switch rating.In an automatic start/stop system, an automatic reset switch is used.Water Temperature Contactor Switch
The water temperature contactor switch is located in the cylinder head. High water temperature closes the switch to activate an alarm or fuel shutoff. No resetting is required. The switch opens as the coolant cools.
The sensing element must be submerged in the coolant to operate. Be sure to have an adequate water supply in the jacket water system, or engine damage could result.
Water Level Switch
Typical water level switch, mounted on the side of an expansion tank.If the coolant water level drops below the minimum level, the switch