Rating:
Information element sub-assy, Denso
ZEXEL
138101-1420
PUMP ELEMENTS
157-0
138101-1420
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$42.98
09 Jul 2024
CN: Diesel Injection Par
Cabezales 6Pcs Diesel Plunger Fuel Pump Elements 090150-1570 157-0 138101-1420 Diesel Pump Fuel Plunger Barrel Assembly 22104-1050 Fit for HINO EB300
Cabezales Manufacturer MFR Number:090150-1570 138101-1420 22104-1050 Stamping No.: 157-0 || Package: 6 pieces of plunger and barrel.Neutral packing. || Application:Fit for HINO EB300 . || Compatible with Fuel Injection Pump: 090100-3930 090100-4440 090100-2830 || Notice:Please you carefully check your vehicle plunger barrel and make sure that the number must be completely the same as our description fitment,if you have any problem,please you contact us by email,we will have professional customer service within 24 hours.
Cabezales Manufacturer MFR Number:090150-1570 138101-1420 22104-1050 Stamping No.: 157-0 || Package: 6 pieces of plunger and barrel.Neutral packing. || Application:Fit for HINO EB300 . || Compatible with Fuel Injection Pump: 090100-3930 090100-4440 090100-2830 || Notice:Please you carefully check your vehicle plunger barrel and make sure that the number must be completely the same as our description fitment,if you have any problem,please you contact us by email,we will have professional customer service within 24 hours.
$30.99
09 Jul 2024
CN: Diesel Injection Par
Cabezales Diesel Plunger Fuel Pump Elements 090150-1570 Diesel Pump Fuel Plunger Barrel Assembly 157-0 138101-1420 22104-1050 Fit for HINO EB300 Pack of 4
Cabezales Manufacturer MFR Number:090150-1570 138101-1420 22104-1050 Stamping No.: 157-0 || Package: 4 pieces of plunger and barrel.Neutral packing. || Application:Fit for HINO EB300 . || Compatible with Fuel Injection Pump: 090100-3930 090100-4440 090100-2830 || Notice:Please you carefully check your vehicle plunger barrel and make sure that the number must be completely the same as our description fitment,if you have any problem,please you contact us by email,we will have professional customer service within 24 hours.
Cabezales Manufacturer MFR Number:090150-1570 138101-1420 22104-1050 Stamping No.: 157-0 || Package: 4 pieces of plunger and barrel.Neutral packing. || Application:Fit for HINO EB300 . || Compatible with Fuel Injection Pump: 090100-3930 090100-4440 090100-2830 || Notice:Please you carefully check your vehicle plunger barrel and make sure that the number must be completely the same as our description fitment,if you have any problem,please you contact us by email,we will have professional customer service within 24 hours.
Include in ##:
Cross reference number
Part num
Firm num
Firm
Name
09015-01570
22104-1050
ELEMENT SUB-ASSY,
0901501570
22104-1050
HINO
ELEMENT SUB-ASSY,
Information:
aslink" data-element=".content_table_1">
TECHNICAL INFORMATION BULLETIN March 27, 2002
Engines 3516 (25Z, 5SJ, 7KM, CMD, 4XF)
3516B (1HZ, 7RN, 5AN, FDN, BDP,
6HN)
Component Code: 1404SUBJECT: Generator Stator Adapter Cracking on 3516 Diesel Generator Set
PROBLEM:
Certain SR4B single bearing generators may develop cracks in the adapter assembly. The generator adapter is the welded assembly, part of the generator stator, consisting of the front adapter ring that bolts to the flywheel housing and the individual support bars welded to this adapter ring. Several different weld failure modes exist for the generator adapter. First, there may be cracks along the top weld leg between the adapter supports and the front adapter ring. Second, there may be cracks at the toe of the welds joining the adapter support bars to the front ring. These cracks appear in the heat-affected zone of the welds and propagate into the front adapter ring of the generator. The third failure mode is radial cracks between the end ring of the generator adapter and the stator housing. This type of crack most likely occurs after the support welds have failed. After the support welds have failed, the cracks at the toe of the support bars propagate into the ring and create a stress riser.
SOLUTION:
Caterpillar is redesigning the current product and is also working on a solution that will address the existing units in the field. At this time, it is NOT recommended to immediately replace cracked generator stators, nor is it recommended to re-weld the cracked adapters as a field repair. Rather, a crack observation and evaluation process should be established for each individual case. It is anticipated that the first recognizable cracks on suspect generators (cracks size of 0.25" and larger) may appear as early as 300 hours. If any of the above-described cracks are found, the servicing dealer should contact Caterpillar Service. The servicing dealer should also assist in periodic inspection of the cracks in an effort to determine the next action.
Contact (if different from sender): Miro Halicek (770) 233-5877 or Marc Sylvester (770) 233-5630.
COPYRIGHT 2002 CATERPILLAR
ALL RIGHTS RESERVED
TECHNICAL INFORMATION BULLETIN March 27, 2002
Engines 3516 (25Z, 5SJ, 7KM, CMD, 4XF)
3516B (1HZ, 7RN, 5AN, FDN, BDP,
6HN)
Component Code: 1404SUBJECT: Generator Stator Adapter Cracking on 3516 Diesel Generator Set
PROBLEM:
Certain SR4B single bearing generators may develop cracks in the adapter assembly. The generator adapter is the welded assembly, part of the generator stator, consisting of the front adapter ring that bolts to the flywheel housing and the individual support bars welded to this adapter ring. Several different weld failure modes exist for the generator adapter. First, there may be cracks along the top weld leg between the adapter supports and the front adapter ring. Second, there may be cracks at the toe of the welds joining the adapter support bars to the front ring. These cracks appear in the heat-affected zone of the welds and propagate into the front adapter ring of the generator. The third failure mode is radial cracks between the end ring of the generator adapter and the stator housing. This type of crack most likely occurs after the support welds have failed. After the support welds have failed, the cracks at the toe of the support bars propagate into the ring and create a stress riser.
SOLUTION:
Caterpillar is redesigning the current product and is also working on a solution that will address the existing units in the field. At this time, it is NOT recommended to immediately replace cracked generator stators, nor is it recommended to re-weld the cracked adapters as a field repair. Rather, a crack observation and evaluation process should be established for each individual case. It is anticipated that the first recognizable cracks on suspect generators (cracks size of 0.25" and larger) may appear as early as 300 hours. If any of the above-described cracks are found, the servicing dealer should contact Caterpillar Service. The servicing dealer should also assist in periodic inspection of the cracks in an effort to determine the next action.
Contact (if different from sender): Miro Halicek (770) 233-5877 or Marc Sylvester (770) 233-5630.
COPYRIGHT 2002 CATERPILLAR
ALL RIGHTS RESERVED