09010-09000 BODY ASSY, INJECTI Denso Cross


Rating:
29
Buy BODY ASSY, INJECTI 09010-09000 genuine, new aftermarket engine parts with delivery

Information body assy, injecti Denso

KIT List:

Part name
Kit1
Kit2
Body assy, injecti
Body assy, injecti
Body assy, injecti
Body assy, injecti
Body assy, injecti
Body assy, injecti
Body assy, injecti

Scheme #.#:

Qty
Part num
Name
Remarks
Manufacture num
000
[01]
09010-09000
BODY ASSY, INJECTI
A4
001
[01]
HOUSING KIT, INJEC
001-001
[03]
BOLT, STUD
M6,L26
003
[04]
HOLDER, DELIVERY V
004
[04]
STOPPER, DELIVERY
005
[04]
SPRING, DELIVERY V
006
[04]
GASKET, DELIVERY V
007
[04]
VALVE SUB-ASSY, IN
MK:1250
008
[04]
ELEMENT SUB-ASSY,
MK:3110
009
[04]
PINION, PLUNGER CO
010
[04]
SCREW, PLUNGER CON
011
[04]
SLEEVE, PLUNGER CO
012
[04]
SEAT, SPRING, UPR
-9301
012
[04]
SEAT, SPRING, UPR
9301-
013
[04]
SPRING, PUMP PLUNG
-9204
013
[04]
SPRING, PUMP PLUNG
9204--9312
013
[04]
SPRING, PUMP PLUNG
9401-
014
[04]
SEAT, SPRING, LWR
015
[04]
TAPPET SUB-ASSY,IN
016
[04]
PLUG, INJECTION PU
017
[01]
CAMSHAFT, INJECTIO
018
[01]
RING, CAMSHAFT ADJ
019
[3C]
PLATE, CAMSHAFT SH
T0.1
019
[3C]
PLATE, CAMSHAFT SH
T0.12
019
[3C]
PLATE, CAMSHAFT SH
T0.14
019
[3C]
PLATE, CAMSHAFT SH
T0.16
019
[3C]
PLATE, CAMSHAFT SH
T0.18
019
[3C]
PLATE, CAMSHAFT SH
T0.5
019
[3C]
PLATE, CAMSHAFT SH
T0.3
019
[3C]
PLATE, CAMSHAFT SH
T1.0
019
[3C]
PLATE, CAMSHAFT SH
T1.5
019
[3C]
PLATE, CAMSHAFT SH
T2.0
019
[3C]
PLATE, CAMSHAFT SH
T0.03
020
[01]
COVER, BEARING
021
[01]
GASKET, BEARING CO
022
[01]
RACK, CONTROL
023
[01]
SCREW, RACK GUIDE
024
[04]
WASHER, FUEL PIPE
025
[02]
PLATE SET, VALVE H
026
[04]
O-RING
ID17.8
027
[02]
WASHER, INJECTION
028
[01]
COVER SUB-ASSY, IN
-9509
028
[01]
COVER SUB-ASSY, IN
9510-
028-002
[02]
PACKING, AIR BLEED
028-003
[02]
SCREW
028-006
[01]
PROCESSING DRAWING
028-007
[01]
GASKET, INJECTION
029
[4C]
PLATE, TAPPET ADJU
T0.6
029
[4C]
PLATE, TAPPET ADJU
T0.7
029
[4C]
PLATE, TAPPET ADJU
T0.8
029
[4C]
PLATE, TAPPET ADJU
T0.9
029
[4C]
PLATE, TAPPET ADJU
T1.0
029
[4C]
PLATE, TAPPET ADJU
T1.1
029
[4C]
PLATE, TAPPET ADJU
T1.2
029
[4C]
PLATE, TAPPET ADJU
T1.3
029
[4C]
PLATE, TAPPET ADJU
T1.4
029
[4C]
PLATE, TAPPET ADJU
T0.1
029
[4C]
PLATE, TAPPET ADJU
T0.2
029
[4C]
PLATE, TAPPET ADJU
T0.3
029
[4C]
PLATE, TAPPET ADJU
T0.4
029
[4C]
PLATE, TAPPET ADJU
T0.5
029
[4C]
PLATE, TAPPET ADJU
T0.15
029
[4C]
PLATE, TAPPET ADJU
T0.13
030
[03]
NUT, HEXAGON
M6,L5
031
[03]
WASHER, SPRING
FOR M6
032
[04]
BOLT, W/WASHER
M6,L20
033
[01]
BEARING, ROLLER
034
[01]
VALVE ASSY, OVERFL
2.4-2.8K
035
[01]
O-RING
ID32.0
036
[01]
SCREW, HOLLOW
037
[01]
SCREW, HOLLOW
043
[01]
BEARING, ROLLER
044
[01]
RING, CAMSHAFT ADJ
046
[3C]
PLATE, CAMSHAFT SH
T0.1
046
[3C]
PLATE, CAMSHAFT SH
T0.15
046
[3C]
PLATE, CAMSHAFT SH
T0.3
046
[3C]
PLATE, CAMSHAFT SH
T0.5
046
[3C]
PLATE, CAMSHAFT SH
T1.0
046
[3C]
PLATE, CAMSHAFT SH
T1.5
046
[3C]
PLATE, CAMSHAFT SH
T0.12
046
[3C]
PLATE, CAMSHAFT SH
T0.14
046
[3C]
PLATE, CAMSHAFT SH
T0.18
046
[3C]
PLATE, CAMSHAFT SH
T0.03

Cross reference number



Part num
Firm num
Firm
Name
09010-09000 
 
BODY ASSY, INJECTI




Information:

Clean and Inspect
Before working inside the generator, make sure that the starter motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator:1. The regulator terminal strip2. The excitation transformer terminal strip (self-excited generator only).Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.An electrical shock can be received from the regulator capacitor (C1) when the engine-generator is not in operation. To avoid possible injury, discharge the stored charge using an 100 ohm resistor across C1 terminals.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
If Moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check that all circuit boards are fully plugged in their sockets. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required. Refer to the "Electric Set Generator Service Manual" for testing and adjusting or disassembly and assembly procedures.Space Heaters
The SR4 generator can operate in high humidity conditions without problems. However, problems can occur when the generator is idle and the surrounding air is warmer than the generator. Moisture can form on the windings and result in poor performance and even result in damage to the windings. Whenever the generator is not in use, insure that the space heaters are in operation.An external source of either 115 or 230 (200 v at 50 Hz) volts A.C. is required to operate the space heaters. Space Heater Connection to External Source H1, H2, H3, H4. Terminal Strip Terminals If 115 VAC source is available, connect both heaters in parallel across the source (L1-L2). If 230 VAC source is available, connect both heaters in

Have questions with 09010-09000?





Group cross 09010-09000

Back to top